Irda & Ask Diagnostics; Irda & Ask Check; Irda & Ask Check (Checker Mode); Data Transmission Check (Receive Mode) - Sharp ER-A750 Service Manual

For "u" & "a" version
Hide thumbs Also See for ER-A750:
Table of Contents

Advertisement

The above operation is repeated.
3 Error display
Data Transmission Check (Master)
Input Master Terminal Number
xxx
Input Satellite Terminal Number : xxx
xxx xxx xxx xxx xxx
Data Sequence Number
: xxxx
IRC Error
: xx —
The error codes are as shown below.
01 Command abnormality (except for during transmission)
02 No data received.
03 Received data present.
Received data remained.
04 Remote station not ready (in sending)
"NTDY" is sent back because the remote station is not ready
for reception.
05 Reception buffer full (in sending)
The controller reception buffer of the remote machine is full.
06 Resend error (in sending)
Retry over (5 times) when no response
07 Collision error (in sending)
When an collision occurred in data transmission, retry over
(16 times) at re-collision after a random time (0
08 Line busy time out
Transmission cannot be made by multi-station communication
to cause time out in data send wait time.
09 Reception size over (in receiving)
The reception buffer size is insufficient.
0A Hardware error
Interface abnormality (No SRN interface or abnormality in
SRN controller)
3 Terminating procedure
Press the CANCEL key to terminate the check. After terminating,
perform the service reset.
3-9. IrDA & ASK Diagnostics
This is used to check the IR communication.
To execute this check, the following composition is required.
ER-A750
ER-A750 as checker
The following menu is displayed. The cursor position is highlighted.
Use
key and
key to move the cursor. Move the cursor to the
process you desire and press the enter key. The selected individual
diagnostics program is executed. When the CANCEL key is pressed,
the display returns to the diagnostics menu.
IR (IrDA & ASK) Diagnostics
IrDA§&§ASK§Check
IrDA & ASK Check (CHECKER MODE)

Data Transmission Check (Receive MODE)

Data Transmission Check (Send MODE)
1) IrDA & ASK Check
IR communication is checked between the ER-A750 sending unit and
the receiving unit.
1 Check content
:
The error
code is
displayed.
2 Display
IrDA & ASK Check
DATA (or TIMEOUT) :
3 Terminating procedure
Press the CANCEL key to terminate the check.
2) IrDA & ASK Check (checker mode)
255ms).
Set the checker machine (ER-A750) corresponding to the above
check content (1).
2 Display
IrDA & ASK Check (CHECKER MODE)
DATA (or TIMEOUT) :
3 Terminating procedure
Press the CANCEL key to terminate the check.
3) Data Transmission Check (Receive mode)
1 Check content
Continuous IR communication between the ER-A750 and the ER-
A750. This mode is on the reception side. When data of 256byte
(00H
one. Check that the counter increments.
2 Display
Data Transmission Check (Receive MODE)
COUNTER :
3 Terminating procedure
Press the CANCEL key to terminate the check.
6 – 10
Data transmission is made from the machine to be checked in
ASK format. The transmission rate is 9600bps. Data of 00H,
11H, 22H, 33H, 44H, 55H, 66H, 77H, 88H, 99H, AAH, BBH,
CCH, EEH, and FFH are transmitted.
The checker machine sends back the received data.
The machine to be checked compares the data sent back and
the data transmitted first. If both data are the same, it displays
"PASS !!," and if not the same, "ERROR !!."
Data transmission is made from the machine to be checked in
IrDA format. The transmission rate is 9600bps. Data of 00H,
11H, 22H, 33H, 44H, 55H, 66H, 77H, 88H, 99H, AAH, BBH,
CCH, EEH, and FFH are transmitted.
The checker machine sends back the received data.
The machine to be checked compares the data sent back and
the data transmitted first. If both data are the same, it displays
"PASS !!," and if not the same, "ERROR !!."
PASS!!(or ERROR!!)
PASS!!(or ERROR!!)
0FFH) are received, data packet counter is incremented by
**** (The RING COUNTER (0-9999) is displayed.)