Acoustics; Test For Prominent Discrete Tones (Pdts); Lectromagnetic Mmunity - Seagate ST500LM000 Product Manual

Laptop thin sshd
Hide thumbs Also See for ST500LM000:
Table of Contents

Advertisement

2.8.2.2
Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degradation
in performance when subsequently put into operation are specified below.
5–500 Hz
5.0 Gs (0 to peak). Max displacement may apply below 22 Hz.
2.9
A
COUSTICS
Drive emission of sound is measured consistent with the ECMA-74 and its referenced standards. Testing is conducted at
room temperature (approximately 25°C). Emission levels are reported as the total A-weighted sound power levers for steady
state, idle, and active seeks modes of operation.
Table 6
Drive A-weighted Sound Power Levels (SWL, BA)
(1)
I
DLE
2.0 bels (typ)
2.2 bels (max)
1.
During periods of drive idle, some offline activity may occur according to the S.M.A.R.T.
specification, which may increase acoustic and power to operational levels.
2.9.1

Test for prominent discrete tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use
of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to discern tone audibility and to
compensate for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74
standards.
*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.
2.10
E
LECTROMAGNETIC
When properly installed in a representative host system, the drive operates without errors or degradation in performance
when subjected to the radio frequency (RF) environment as defined in
Table 7 Radio Frequency Environments
T
EST
Electrostatic discharge
Radiated RF immunity
Electrical fast transient
Surge immunity
Conducted RF immunity
Power Frequency H-field
immunity
Voltage dips, interrupts
S
L
T
SSHD SATA P
EAGATE
APTOP
HIN
P
ERFORMANCE
I
MMUNITY
D
ESCRIPTION
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
± 1 kV on AC mains, ± 0.5 kV on external I/O
± 1 kV differential, ± 2 kV common, AC mains
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine
1 A/m, 50Hz/60Hz, 3 axes
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
M
, R
RODUCT
ANUAL
S
EEK
2.2 bels (typ)
2.4 bels (max)
.
Table 7
. D
EV
D
S
RIVE
PECIFICATIONS
P
R
ERFORMANCE
EFERENCE
L
S
EVEL
TANDARD
B
EN 61000-4-2: 95
EN 61000-4-3: 96
A
ENV 50204: 95
B
EN 61000-4-4: 95
B
EN 61000-4-5: 95
A
EN 61000-4-6: 97
A
EN 61000-4-8: 97
C
C
EN 61000-4-11: 94
B
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St500lm001St320lm002St500lm020

Table of Contents