Table 4-3 Using the Configuration and Diagnostic Program
Task
To select buttons
To select other items
To escape a screen
To get help

Running Group 1 Tests

Be sure that the NIC is installed correctly. Then follow these
steps to run the Group 1 tests:
1 Boot the PC under DOS.
The Configuration and Diagnostic Program is a DOS
application. It must be run in DOS, not in a DOS window.
It will not run if memory managers or other device drivers
have been loaded.
2 Insert the 3Com diskette in the drive and make that
the active drive.
3 Enter this command at the DOS prompt to start the
Configuration and Diagnostic Program:
3c395cfg
4 From the Test menu, select Run Tests.
The Run dialog box appears. The Start button is selected.
5 To start the tests, press Enter.
The test results are displayed on the screen in the
Results column.
Group 1 tests run ten times unless you specify otherwise.
To run the tests continuously:
a Go to the Repetitions box on the Test Setup screen.
b Select Continuous.
c Deselect Halt on Error in the Errors box.
For test descriptions, press F1 to see online Help.
6 When you have finished testing the NIC, exit the
Configuration and Diagnostic Program and reboot
the PC.
DOS Diagnostic Tests
Action
Press Tab and then press Enter.
Use the arrow keys, and press Enter.
Press Esc.
Select an item and press F1.