Remove the access panel
WARNING:
internal system components to cool before touching them.
CAUTION:
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
To remove the component:
Power down the server (on page 20).
1.
Extend the server from the rack (on page 20).
2.
Open the locking latch, slide the access panel to the rear of the chassis, and remove the access
3.
panel.
If the locking latch is locked use a T-15 Torx screwdriver to unlock the latch.
Install the access panel
Place the access panel on top of the server with the hood latch open. Allow the panel to extend past
1.
the rear of the server approximately 1.25 cm (0.5 in).
Push down on the hood latch. The access panel slides to a closed position.
2.
Use the T-15 Torx screwdriver provided with the server to tighten the security screw on the hood
3.
latch.
Remove the BBWC battery pack
Power down the server (on page 20).
1.
Extend the server from the rack (on page 20).
2.
Remove the access panel (on page 22).
3.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
Do not operate the server for long periods with the access panel open or removed.
Operations 22