INSTALLATION

ATTENTION: 2 people are required for proper installation; the unit should be installed by a qualified
operator.
INSTALLATION IN DUCTING VERSION:
1.
Before fixing, the disposal duct for air evacuation to the outside must be installed. Use an disposal duct with:
– minimum indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified material
(according to the State); – an as smooth as possible inside. It is also advisable to avoid any drastic changes in pipe
cross-section. We recommend using a 200 mm diameter pipe. For air evacuation to the outside, follow all the other
instructions given on the "Warnings" sheet.
2.
You have purchased the 2-motor version (model shown in Fig. 2); you must fit the plastic flange using 4
screws (the screws are provided and are the 4 shortest ones).
3.
Prepare a suitable power supply. For the electrical connection, follow all the other instructions on the
"Warnings" sheet.
4.
Check to see the grease filters have been removed; if necessary, remove these by moving the catch (B)
and turning these outwards (Fig. 3).
5.
Make a hole for housing the appliance (Fig. 4) in the bottom of the wall unit. The bottom of the wall unit must
have a thickness of between 15 and 20 mm.
6.
Take 4 retention screws from the accessories bag. Fit the appliance in the hole made on the wall unit, first
positioning the rear part, so the flap on the back rests on the wall unit; next, slightly slide the appliance back, towards
the wall (Fig. 5).
Without leaving the appliance, secure this to the wall unit by means of the 4 screws (Fig. 6).
7.
Proceed with final fitting, using the 4 screws (the longest ones); See Fig. 7.
8.
Connect the disposal duct to the air evacuation pipe of the hood. Use a flexible pipe and lock it to the air
evacuation pipe of the hood with a metal hose clamp (pipe and clamp are not provided). Make the electrical
connections.
9.
Refit the grease filters.

OPERATION

Controls (Fig. 8):
Button A: turns the lights on/off; every 30 hours of operation the corresponding pilot lamp (S) comes on to indicate
that the grease filters must be cleaned; every 120 hours of operation the corresponding pilot lamp (S) flashes to
indicate that the grease filters must be cleaned. To restart the hour counter (RESET), hold the button A pressed down
for about 1" (while the pilot lamp S is on).
Button B: drives the motor in first speed (the corresponding pilot lamp comes on); when holding it down for about 1",
the motor cuts out; when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and
thus the motor stops after 5' (the pilot lamp flashes).
Button C: drives the motor in second speed (the corresponding pilot lamp comes on); when pressing the button a
second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp
flashes).
Button D: drives the motor in third speed (the corresponding pilot lamp comes on); when pressing the button a second
time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes).
Button E: drives the motor in fourth speed (the corresponding pilot lamp comes on); when pressing the button a
second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp
flashes).
Pay special attention to the grease filters: the grease filters must be cleaned approximately once every 30 hours
of operation (when the light button lamp comes on) - Fig. 8S). Wash out the filter using a neutral soap. Once the
cleaned filters are reinstalled, to reset the counter hold the light button pressed down for about 1" (Fig. 8A) while the
corresponding pilot lamp (S) is on.
Removing the grease filters: Remove the grease filters by moving fastener B and turning the filter outwards
(Fig. 3).
Lighting: to remove the halogen lamps, turn the locknut counter-clockwise (Fig. 9). Replace with the same type
of lamp. CAUTION: Do not handle glass bulb with bare hands.
DEUTSCH
HINWEIS
Der Mindestabstand zwischen der Topf-Trägerfläche auf der Kochmulde und dem unteren Teil der Abzughaube
muss 65 cm betragen. Geben die Installationsanleitungen der Kochmulde einen höheren Abstand an, so ist
dieser einzuhalten.
Ein Anschluss der Abluftleitungen an Verbrennung-sabgaskamine (zum Beispiel Zentralheizung, Heizgeräte,
Badezimmeröfen
usw.) ist nicht gestattet.
In jedem Fall sind bei der Ableitung der Abluft die behördlichen Vorschriften zu beachten. Desweiteren darf die