Replacement Of Parts; Access; Replacement Procedure; Electrical Components - Keston Qudos 28s User, Installation And Servicing Instructions

Fan powered high efficiency modulating domestic condensing gas system boiler
Table of Contents

Advertisement

WD420/3/2007
Boilers
CONTENTS
8.0
GENERAL
8.1
PRECAUTIONS
8.2

ACCESS

8.3

REPLACEMENT PROCEDURE

8.4

ELECTRICAL COMPONENTS

8.4.1
8.4.2
8.4.3
8.4.4
8.4.5
8.4.6
8.4.7
8.4.8
8.4.9
8.5
SPARK IGNITION/FLAME DETECTION ELECTRODE
8.6
BURNER
8.7
HEAT EXCHANGER
8.8
CONDENSATE TRAP
8.9
PUMP
8.10
EXPANSION VESSEL
8.0
GENERAL
The following must always be carried out by a competent/qualified person.
8.1
PRECAUTIONS
i)
Always switch off the mains electricity supply and disconnect the plug at the isolating
switch and socket. (If a switch only is used then remove the fuse.)
ii)
Gain access to the appliance (Section 8.2) and turn off the gas supply at the
appliance service cock.
WARNING :
8.2
ACCESS
i)
Remove the cabinet by removing the screws to the top and bottom of the cabinet.
8.3
REPLACEMENT PROCEDURE
i)
Always replace in the reverse order unless otherwise stated.
ii)
Electrical connections must be remade in accordance with the Electrical Wiring
Diagram (Section 6.5).
iii)
Test the tightness of any gas carrying or water carrying joint broken during the service
procedures.
8.4
ELECTRICAL COMPONENTS
8.4.1
Control Panel (Fig. 6.7.1 item 132)
i)
ii)
iii)
iv)
Installation & Servicing Instructions
Chapter 8 : Replacement Of Parts

8. REPLACEMENT OF PARTS

CONTROL PANEL
BOILER FLOW & RETURN THERMISTORS
CABINET TEMPERATURE SENSOR
FLUE THERMISTOR
PRESSURE SENSOR
MAIN CONTROL PCB
COMBUSTION BLOWER
GAS CONTROL VALVE
FLOW THERMOSTAT
Parts of the boiler internal wiring will remain live even after setting the
User Controls to Standby. Shut off the power supply at the isolating
switch before working on the appliance.
Isolate the appliance (Section 8.1)
Gain access (Section 8.2)
Remove the user control cover by removing the four retaining screws (Fig
6.7.1, item 143 and item 144).
Disconnect the Control Panel by unplugging the cable connector.
The Keston Qudos 28s & Qudos 28sP
Page : 46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qudos 28sp

Table of Contents