Replacement Of Parts - Keston Qudos 37 User's Installation Manual

Fan powered high efficiency modulating domestic condensing gas boiler
Table of Contents

Advertisement

WD500
CONTENTS
8.0
GENERAL
8.1
PRECAUTIONS
8.2
ACCESS
8.3
REPLACEMENT PROCEDURE
8.4
ELECTRICAL COMPONENTS
8.4.1
8.4.2
8.4.3
8.4.4
8.4.5
8.4.6
8.4.7
8.4.8
8.5
SPARK IGNITION/FLAME DETECTION ELECTRODE
8.6
BURNER
8.7
HEAT EXCHANGER
8.8
CONDENSATE TRAP
8.9
PUMP
8.0
GENERAL
The following must always be carried out by a competent/qualified person.
8.1
PRECAUTIONS
i)
Always switch off the mains electricity supply and disconnect the plug at the isolating
switch and socket. (If a switch only is used then remove the fuse.)
ii)
Gain access to the appliance (Section 8.2) and turn off the gas supply at the
appliance service cock.
WARNING :
8.2
ACCESS
i)
Remove the cabinet by removing the screws to the top and bottom of the cabinet.
8.3
REPLACEMENT PROCEDURE
i)
Always replace in the reverse order unless otherwise stated.
ii)
Electrical connections must be remade in accordance with the Electrical Wiring
Diagram (Section 6.5).
iii)
Test the soundness of any gas carrying or water carrying joint broken during the
service procedures.
8.4
ELECTRICAL COMPONENTS
8.4.1
Control Panel (Fig. 6.7.1 - item 112)
i)
ii)
iii)
iv)
v)
vi)
8.4.2
Boiler Flow and Return Thermistors (Fig. 6.7.2 - item 70)
i)
ii)
iii)
Installation & Servicing Instructions
Chapter 8 : Replacement Of Parts

8. REPLACEMENT OF PARTS

CONTROL PANEL
BOILER FLOW & RETURN THERMISTORS
CABINET TEMPERATURE SENSOR
FLUE THERMISTOR
PRESSURE SENSOR
MAIN CONTROL BOX
COMBUSTION BLOWER
GAS CONTROL VALVE / VENTURI ASSEMBLY
Parts of the boiler internal wiring will remain live even after setting the
User Controls to Standby. Shut off the power supply at the isolating
switch before working on the appliance.
Isolate the appliance (Section 8.1)
Gain access (Section 8.2)
Remove the user control cover by removing the three retaining screws (Fig
6.7.1 - item 117).
Disconnect the Control Panel by unplugging the cable connectors.
Reassemble (Section 8.3)
Check for correct operation of the Control Panel.
Isolate the appliance (Section 8.1)
Gain access (Section 8.2)
Remove the push on connectors from the thermistor taking note of the correct
positions.
The Keston Q37 & Q37P Boilers
Page : 44