Boiler Flow And Return Thermistors; Cabinet Temperature Sensor; Flue Thermistor; Pressure Sensor - Keston Qudos 28s User, Installation And Servicing Instructions

Fan powered high efficiency modulating domestic condensing gas system boiler
Table of Contents

Advertisement

WD420/3/2007
Boilers
v)
vi)
vii)
8.4.2
Boiler Flow and Return Thermistors (Fig. 6.7.2 - 1/2 & 2/2 item 58)
i)
ii)
iii)
iv)
v)
8.4.3
Cabinet Temperature Sensor (Fig 6.7.1 item 151)
i)
ii)
iii)
iv)
8.4.4
Flue Thermistor (Fig. 6.7.2 - 1/2 item 59)
i)
ii)
iii)
iv)
v)
8.4.5
Pressure Sensor (Fig. 6.7.2 - 2/2 item 101)
i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
8.4.6
Main Control PCB (Fig. 6.7.1 item 131)
i)
ii)
iii)
iv)
v)
vi)
Installation & Servicing Instructions
Chapter 8 : Replacement Of Parts
Remove the Control Panel by removing the four retaining screws (Fig 6.7.1,
item 160).
Reassemble (Section 8.3)
Check for correct operation of the Control Panel.
Isolate the appliance (Section 8.1)
Gain access (Section 8.2)
Remove the push on connectors from the thermistor taking note of the correct
positions.
Unclip the thermistor from the pipe.
Reassemble (Section 8.3)
NB:
When fitting the new thermistor it is an advantage to smear a thin film
of heat sink compound between the thermistor and pipe. This,
combined with fitting the new thermistor tightly to the pipe, ensures a
good contact.
Isolate the appliance (Section 8.1)
Gain access (Section 8.2)
Remove the cabinet temperature sensor from the connector block by
slackening the retaining screws.
Reassemble (Section 8.3)
Isolate the appliance (Section 8.1)
Gain access (Section 8.2)
Remove the push on connectors from the thermistor taking note of the correct
positions.
Unscrew the retaining nuts, and remove the thermistor.
Reassemble (Section 8.3)
NB:
When fitting the new thermistor it is an advantage to smear a thin film
of heat sink compound between the thermistor and plate. This,
combined with fitting the new thermistor tightly to the plate, ensures a
good contact.
Isolate the appliance (Section 8.1)
Shut off the water supply to the appliance.
Gain access (Section 8.2)
Drain the system to below the level of the appliance.
Remove the push on connector from the pressure sensor.
Unscrew the pressure sensor.
Reassemble (Section 8.3).
NB:
Use a little jointing compound or PTFE tape on the thread.
Refill the system (See Section 5 - Commissioning).
NB:
When reassembling inspect the oring (Fig 6.7.2 - 2/2, item 100) for
damage and replace if necessary.
Isolate the appliance (Section 8.1)
Gain access (Section 8.2)
Pull off the multi-pin connectors and HT lead away from the board.
Remove the plastic box cover by pulling it from support.
Remove the control PCB by pulling it from the four support plastic pins.
Reassemble (Section 8.3)
The Keston Qudos 28s & Qudos 28sP