Fault Modes; Error Codes - Keston Qudos 28s User, Installation And Servicing Instructions

Fan powered high efficiency modulating domestic condensing gas system boiler
Table of Contents

Advertisement

WD420/3/2007
6.3

FAULT MODES

If a situation is detected which the boiler considers may cause damage to the appliance the boiler
will enter a lockout mode and stop functioning. After clearing the problem the user must also press
the "Reset" button once to resume boiler operation in most circumstances. However, certain
faults, as designated "Service Reset Required" in the table below, will not reset from the fascia
button. These require the Service Reset button on the main PCB (see Fig 6.5) to be pressed. IN
BOTH TYPES OF LOCKOUT, TURNING THE POWER ON THEN OFF WILL NOT CLEAR A
LOCKOUT SITUATION

ERROR CODES

Display
Description of fault
E01
Flame sequence lockout - possible board or electrical supply fault.
E02
Ignition failure. Boiler made made five unsuccessful attempts to ignite. Check
gas supply, ignitor condition and spark gap. Check flue and air system and
condensate drainage for obstruction. Check gas valve setting and operation
E03
Spark gap too small OR Gas valve faulty - check connections to gas valve and
operation of gas valve solenoids
E04
Flame lost 5 times in a single demand period - check combustion setting high
and low, and ignitor condition
E12
Flow overheat - check water circulation is not blocked, check pump operation
and flow thermistor condition.
E20
Fan unable to reach ignition rate -check fan and impellar restriction
E24
Return exceed flow temperature by 10C - check direction of water circulation and
operation of flow and return thermistors
E25
Flow temperature increased too quickly - check water circulation and pump
operation
E26
Water pressure sensor is open circuit/disconnected
E28
Fan fault - check connector to fan operation of fan
E31
Flow thermistor closed circuit - check the connections and wires to the flow
thermistor are intact not short circuited
E32
Return thermistor closed circuit - check the connections and wires to the return
thermistor are intact not short circuited
E33
DHW thermistor closed circuit - check the connections and wires to the DHW
thermistor are intact not short circuited, if present
E35
Flue thermistor closed circuit - check the connections and wires to the flue
thermistor are intact not short circuited
E36
Flow thermistor open circuit/not connected - check the connections and wires to
the flow thermistor are intact and connected
E37
Return thermistor open circuit/not connected - check the connections and wires
to the return thermistor are intact and connected
E38
DHW thermistor open circuit/not connected - check the connections and wires to
the DHW thermistor are intact and connected, if present
E40
Flue thermistor open circuit/not connected - check the connections and wires to
the flue thermistor are intact and connected - SERVICE RESET REQUIRED
E52
Flue overheat - check combustion and heat exchanger. Reset required on main
PCB - SERVICE RESET REQUIRED
E62
Water pressure is > 2,7 bar - check operation of expansion vessel or filling loop
is left open
E67
Water pressure is < 0.4bar
E70
Cabinet overheat - thermal fuse will need replacing. Check hot gasket joints and
combustion for cause of overheat. Reset required on main PCB - SERVICE
RESET REQUIRED
E73
Code plug error - check loom and connections to main pcb.
E74
Supply voltage < 190V - check mains supply condition
E75
Supply voltage > 270V - check mains supply condition
E76
Solar panel sensor closed circuit - if present.
E77
Solar panel sensor open circuit - if present
E95
Solar tank sensor closed circuit - if present
E96
Solar tank sensor open circuit - if present
Installation & Servicing Instructions
Chapter 6 : Fault Finding
The Keston Qudos 28s & Qudos 28sP Boilers
Page : 33