Checking The Blades; Replacing The Blades; Removing The Bioclip Plug - Husqvarna Rider 115C Operator's Manual

Hide thumbs Also See for Rider 115C:
Table of Contents

Advertisement

Checking the blades

To achieve the best mowing results it is important that the
blades are undamaged and well-sharpened.
Check that the blades' attachment screws are tight.
Put the unit in the service position, see Service position
for the cutting unit.
IMPORTANT INFORMATION
Replacing or sharpening the blades should be conducted
by an authorised service workshop.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles
that result in a breakdown. Let the service centre assess
whether the blade can be sharpened or must be replaced.
WARNING! Do not use blades that are
!
cracked, chipped, or otherwise show signs
of damage or severe wear. Replace the
blades. The risk increases if the blades are
poorly balanced.
Maintenance

Replacing the blades

Put the unit in the service position, see Service position
for the cutting unit.
Remove the equipment frame.
Lock the blade with a wooden block. Loosen the blade bolt
and remove the blade bolt, the washer and the blade.
Assemble the parts in the reverse order.
Tightening torque 45-50 Nm (4.5-5 kpm/32-36 lbft).
!

Removing the BioClip plug

To change a Combi deck from the BioClip function to a cutting
deck with rear ejection, remove the BioClip plug, which is
located under the unit, attached with a screws.
1 Put the unit in the service position, see Service position
for the cutting unit.
2 Loosen the screw holding the plug and remove it.
3 Fit cutting unit.
4 Fit the BioClip plug in the reverse order.
15mm
WARNING! Always use genuine parts.
– 23