GE 5100 Series Owner's Manual page 16

Zoneline heat pump
Table of Contents

Advertisement

Installation Instructions
Remote Control/
Wall Thermostat
A
Metal
cover
over
recessed
connection
space
B
Low fan speed
with Class 2
Class 2
Remote
Remote
Thermostat
Thermostat
10
11
ON
ON
OFF
OFF
Auxiliary Controls
C
6P Plug
Insert
1
Wire nut
6 PCS
RAK147
or equivalent
R
G B Y W
C T'Stat terminals
Class 2 Thermostat
16
The Zoneline can be controlled
by using the controls on the unit
or by a wall thermostat.
Detailed wiring instructions are
packed with the low-voltage con-
nectors in the recessed connection
space on the Zoneline chassis.
To switch to a wall thermostat,
move switch 10 to the ON (up)
position (see illustration B at left).
Connect the unit to a 6-wire Class 2
Remote Thermostat (GE Model
RAK147 or equivalent), as shown
in illustration C at left.
For some applications, it may be
desirable to operate on low fan
speed. Moving the auxiliary switch
11 to the ON (up) position will pro-
vide low fan speed in both heating
and cooling modes.
No external voltage may be applied
to the unit through the Remote
Thermostat terminals.
IMPORTANT:
After the wire connections are
completed, replace the metal cover
to prevent damage to the unit or
personal injury.

Advertisement