GE 5100 Series Owner's Manual page 6

Zoneline heat pump
Table of Contents

Advertisement

Operating Instructions
Other Zoneline features
About Your Heat Pump
To Remove the
Room Cabinet
6
Heat pumps can save money by
removing heat from the outside
air—even when the outside
temperature is below freezing—
and releasing that heat indoors.
To get the best from your heat
pump, don't change the room
thermostat very often. Raising the
heat setting 2–3 degrees may cause
the Zoneline heat pump to use its
electrical heating elements in
order to reach the new tempera-
ture setting quickly.
Additional controls are located
behind the room cabinet.
To remove: Pull out at the bottom to
release it from the tabs. Then lift up.
2
1
The electric heating elements use
much more electricity than heat
pumps and cost more to operate.
Generally, when the outdoor tem-
perature is above 45
heat pump will warm the room.
Below 25 F., the resistance heater
will warm the room.
When the air is between 25 -45 F.,
the unit will automatically deter-
mine the best source of heat to use.
To replace: Place the tabs over
the top rail. Push inward at the
bottom until it snaps into place.
1
2
F., only the