PJLink security authentication
The password used for PJLink is the same as that of the password set for web control.
When using the projector without security authentication, do not set a password for web control.
f For specifications related to PJLink, refer to the website of Japan Business Machine and Information System Industries Association.
URL http://pjlink.jbmia.or.jp/english/

Using Art-Net function

The network function of the projector supports the Art-Net function, and the Art-Net protocol can operate the DMX controller setting, and the
application software can control the projector setting.
CHANNEL DEFINITION
The following table lists the channel definitions used for controlling the projector with the Art-Net function.
Channel
Control details
1
Shutter control
2
Input selection
3
Lens function select
4
Lens control
5
Power supply control
6
Light volume adjustment
7
Lock
168 - ENGLISH
Chapter 6 Appendix — Technical information
Performance
SHUTTER:OPEN
No operation
SHUTTER:CLOSE
No operation
RGB1
RGB2
VIDEO
DVI-D
HDMI
DIGITAL LINK
SDI (only for PT-DZ870U)
No operation
Execute P IN P, USER1
Execute P IN P, USER2
Execute P IN P, USER3
No operation
No operation
Lens H shift
Lens V shift
Lens focus
Lens zoom
Move to the home position
No operation
(-) High speed
Lens
(-) Low speed
adjustment
(-) Fine
adjustment
Adjustment stop
(+) Fine
adjustment
Lens
adjustment
(+) Low speed
(+) High speed
Command performance
execute
Standby
No operation
Power on
100 %
...
0 %
Operation not available
Operation available
Parameter
0-63
64-191
192-255
0-7
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-127
128-135
136-143
144-151
152-255
0-15
16-31
32-47
Operate together with "Lens
adjustment" of the channel 4.
48-63
64-79
Operate together with "Command
80-95
performance execute" of the channel
4.
96-255
0-31
32-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-191
192-255
0
Can be set in 256 steps between
...
100 % and 0 %.
255
0-127
When "Operation not available" is
set, operation of all channels become
128-255
unacceptable.
Remark

Hide quick links: