Send Diagnostic; Figure 161. Address To Translate; Figure 162. Send Diagnostic - IBM IC35L036UWDY10 - Ultrastar 36.7 GB Hard Drive Specifications

3.5 inch scsi hard disk drive
Table of Contents

Advertisement

! Address to Translate contains the address to translate. If the logical block format is specified, the
first four bytes of the field (bytes 6 to 9) contain the LBA and the remainder must be zero. For the
physical format the address must be specified as follows.
Byte
7
6-8
Cylinder Number
9
Head Number
10-13
Sector Number or Bytes from Index

Figure 161. Address to translate

8.34.3 SEND DIAGNOSTIC Page 80
This requests the drive to perform off-line read scan.
Byte
7
0
Page Code = 80h
1
Reserved = 0
2-3
Page Length = 04h
SMART Revision = 03h
4
Reserved = 0
5
(MSB) Off-line Immediate Time
6
7
Figure 162. SEND DIAGNOSTIC Page 80
! Off-line Immediate Time specifies the delay to start the off-line read scan in seconds. When this
value is zero, the drive immediately starts the off-line read scan.
Bit
6
5
4
Bit
6
5
4
Ultrastar 146Z10 hard disk drive specifications
3
2
1
3
2
1
(LSB)
160