Bit
Byte
0
1
2
3
4
to
n
The Page Code specifies either specification (in case of Send Diagnostic command)
or
report (in case of Receive Diagnostic Results command). The controller
supports the following pages.
Page Code
00
H
01
H
02
H
03
H
04
H
05
H
06
H
07
H
08
H
40
H
When any other page code than shown above is specified, the controller returns
CHECK CONDITION status with the ILLEGAL REQUEST sense key.
The Page Length specifies the number of bytes that follow the Page Length field.
SEND DIAGNOSTIC:(1Dh)
6 COMMAND DESCRIPTIONS
Table 6-91 Diagnostic Page Format
7
6
5
0
0
0
Supported Diagnostic Page
Enclosure Configuration Page
Enclosure Control/Status Page
Enclosure Help Text Page
Enclosure String Out/In Page
Enclosure Threshold Out/In Page
Enclosure Array Control/Status Page
Enclosure Element Descriptor Page
Short Enclosure Status Page
Translate Address Page
4
3
Page Code
Reserved
0
0
Page Length (MSB)
Page Length (LSB)
Diagnostic Parameters
Description
OEM MANUAL:K6602771
2
1
0
0
0
0
Revision: 2 / Date: 2002.12.19
Page: 265 / 313