Maytag MLG31PCB Installation Manual page 25

Phase 7 coin
Hide thumbs Also See for MLG31PCB:
Table of Contents

Advertisement

2. Technical Gas Data
a. Gas Specifications
Manifold Pressure*
In-Line Pressure
Shaded areas are stated in metric equivalents
* Measured at gas valve pressure tap when gas valve is on.
Gas Inlet Size (Each Basket [Tumbler])
Btu/hr Input (Each Basket [Tumbler])
Btu/hr Input (Total for Both Baskets [Tumblers])
F.N.P.T. = Female National Pipe Thread
b. Natural Gas
Regulation is controlled by each gas valve's internal regulator. Incoming supply pressure must be
consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water
column (W.C.) pressure.
c. Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so that
the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve
pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or
regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P.
tank) or an external regulator must be added to each dryer.
113203-3
TYPE OF GAS
NATURAL
3.5 inches W.C.
6.0 - 12.0 inches W.C. 14.92 - 29.9 mb
8.7 mb
10.5 inches W.C.
11.0 inches W.C.
68,000
136,000
Maytag
LIQUID PROPANE
26.1 mb
27.4 mb
1/2" F.N.P.T.
17,136 kcal/hr
34,272 kcal/hr
21