Page 1
MLG32PDB Installation Manual 30 lb Stacked Model RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Part No. 113062 - 17...
Page 2
– L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz. Maytag Co. 113062 - 17...
Page 3
Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. 113062 - 17 Maytag Co.
The collection of lint in the burner area and exhaust gas. The instructions should be posted in a prominent ductwork can create a potential fire hazard. location. 113062 - 17 Maytag Co.
Page 6
_____________________________________________________________ WARNING _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ Fire Hazard Dryer must never be operated with the lint filter or _____________________________________________________________ screen not in place, even if an external lint collection system is used. _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ Maytag Co. 113062 - 17...
IMPORTANT: “The dryer must be installed on noncombustible floors only.” The dryer must not be installed or stored in an area where it will be exposed to water or weather. The dryer is for use in noncombustible locations. Maytag Co. 113062 - 17...
IMPORTANT: Exhaust back pressure measured by a manometer at the dryer’s exhaust duct area must be no less than 0 and must not exceed 0.3 in wc when both tumblers are operating. 113062 - 17 Maytag Co.
Page 10
In either case, allow at least twice the diameter of the duct between the duct opening and nearest obstruction. IMPORTANT: Do not use screens, louvers, or caps on the outside opening of the exhaust ductwork. Maytag Co. 113062 - 17...
70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the location service panel. 113062 - 17 Maytag Co.
9/17/08 Contact the dealer who sold the dryer or contact Maytag Co. NOTE: Contact factory for electrical information not listed. IMPORTANT: Any burner changes or conversions must be made by a qualified professional.
Page 13
IMPORTANT: Pipe joint compounds that resist the action of natural gas and L.P. gas must be used. 113062 - 17 Maytag Co.
L.E.D. display will read “SELECT CYCLE.” water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating. Maytag Co. 113062 - 17...
(for both the top tumbler and the bottom NOTE: When ordering replacement parts from the Maytag tumbler). dealer or the Maytag Co. be sure to give them the correct model number and serial number so that your parts order Operating Instructions ________________ can be processed in an expeditious manner.
The accumulation of lint can restrict this airflow. If the guidelines in this section are met, a Maytag dryer will provide many years of efficient, trouble free and most importantly safe operation. Fire Hazard...
(i.e. type of gas and electric voltage, etc.). It _____________________________________________________________ also includes all the necessary data for technical support and parts information. When contacting the Maytag Co., please have the model and serial numbers available. This _____________________________________________________________ information is necessary to ensure proper service and parts information from the manufacturer.