Bin Control - Hoshizaki KMS-1122MLH Instruction Manual

Modular crescent cuber serenity series
Hide thumbs Also See for KMS-1122MLH:
Table of Contents

Advertisement

2. Bin Control

Before operating the icemaker, the bin control assembly must be installed correctly.
Failure to properly install the bin control assembly could result in ice backup and
unit damage.
1) Remove the bin control insulation and bin control cover. See Fig. 6.
2) Remove the bin control bracket, bin control bulb holder, two 4×6 screws, two lock
washers, two flat washers, and two 4×8 screws from the accessory bag.
3) Secure the bin control bracket to the bin control cover using the two 4×6 screws,
two lock washers, and two flat washers.
4) The bin control bulb is located under the control box. Route the bin control bulb and
protective hose through the hole in the bin control bracket as illustrated. NOTICE! Be
careful not to kink the bin control capillary tube.
5) Carefully install the bin control bulb into the bin control bulb holder, then secure the bin
control bulb holder to the bin control bracket using the two 4×8 screws. NOTICE! Place
the bin control capillary tube and protective hose just inside the flange on the bin
control bracket. This helps protect the capillary tube.
6) Lower the bin control assembly into position, then secure the bin control cover with
2 thumbscrews.
7) Replace the bin control insulation in its proper position.
Bin Control
Cover
Slot
Hole
4×8 Screw
Bin Control Bulb
NOTICE
Bin Control
Insulation
4×6 Screw
Lock Washer
Flat Washer
Bin Control Capillary
Tube and Protective Hose
Placed Just Inside Flange
on Bin Control Bracket
Bin Control
Capillary Tube
Protective
Hose
Bin Control Bracket,
Two 4×6 Screws,
Two Lock Washers,
and Two Flat
Washers from
Accessory Bag
Bin Control Bulb Holder and
Two 4×8 Screws from Accessory Bag
15
Control Box
Fig. 6