Download Print this page
Hoshizaki KMS-1122MLH Cleaning & Sanitizing
Hide thumbs Also See for KMS-1122MLH:

Advertisement

Quick Links

Ice Machine
The icemaker must be cleaned & sanitized at least once a year.
Cleaning Prep:
1
Remove the Front Panel, move the
OFF. After 3 min., move the
replace the Front Panel.
2
After 3 min., remove the Front Panel, move the
control switch
to OFF. This removes the cubes from
the evaporator.
3
Remove all ice from the dispenser unit/ice storage bin
ATTENTION! IF ON DISPENSER, turn off the dispenser
power supply after dispensing all the ice.
Cleaning:
Left
Side
Water Tank
4
Remove the Front Panel, move the
DRAIN. Move
control switch
the Front Panel.
5
After 2 minutes, remove the Front Panel, move the
control switch
to OFF.
6
Dilute Hoshizaki Scale Away with warm water (see Table below).
Remove the Front, Apron, Top, Left, & Left Insulation Panels
and pour cleaning solution into the water tank.
KMS-1122MLH(3)
Scale Away
27 fl. oz (800 ml)
Warm Water
5 gal. (19 l)
#51008 | 9.15.2016
Cleaning & Sanitizing
control switch
control switch
to ICE, then
Top
Service Switch
Control Switch
Front of icemaker
Drain Plug
service switch
to SERVICE. Replace
 continued on the back...
Tech Support: 1.800.233.1940
to
3
min.
.
to
After 2 min.
KMS-1122MLH(3)
ATTENTION!
Do not leave icemaker
unattended when panels are off
3
min.
AMMONIA
Cleaners
Sanitizing:
 Dilute 5.25% chlorine
bleach* with warm water
(see Table below)
KMS-1122MLH(3)
Bleach
2.5 fl. oz (74 ml)
Warm Water
5 gal. (19 l)
* Use bleach without additives.
 Remove the front, apron,
top, left, & left insulation
panels
 Pour the sanitizing solution
into the water tank
 Replace all the panels, except
the front panel
 Move
service switch
WASH and
control switch
SERVICE, replace the front
panel
 After 15 minutes, remove
front panel
 Move
service switch
replace the front panel
 After 2 minutes, remove
front panel
 Move
control switch
15
16
17
to
to
18
to DRAIN,
19
to OFF
Page 1

Advertisement

loading

Summary of Contents for Hoshizaki KMS-1122MLH

  • Page 1 After 2 minutes, remove the Front Panel, move the After 2 min. control switch to OFF.  After 2 minutes, remove Dilute Hoshizaki Scale Away with warm water (see Table below). front panel Remove the Front, Apron, Top, Left, & Left Insulation Panels  Move control switch to OFF and pour cleaning solution into the water tank.
  • Page 2 Need Service or Repair? Locate your closest Hoshizaki Certified Service Tech: hoshizakiamerica.com/locate-service-rep  sanitizing continued… In bad water conditions, a more thorough cleaning may be required. Move control switch to OFF, then turn off RINSE 1: (Steps 20-22) the power supply. Dilute 5 oz. of Scale Away to 1 ...