Hoshizaki KMS-1230MLH Instruction Manual
Hoshizaki KMS-1230MLH Instruction Manual

Hoshizaki KMS-1230MLH Instruction Manual

Modular crescent cuber serenity series
Hide thumbs Also See for KMS-1230MLH:

Advertisement

Quick Links

Hoshizaki
Hoshizaki America, Inc.
"A Superior Degree
of Reliability"
www.hoshizaki.com
Modular Crescent Cuber
Serenity Series
Model
KMS-1230MLH
Including
Condensing Unit Model SRK-13H
INSTRUCTION MANUAL
Issued: 1-29-2007

Advertisement

Table of Contents
loading

Summary of Contents for Hoshizaki KMS-1230MLH

  • Page 1 Hoshizaki America, Inc. “A Superior Degree of Reliability” www.hoshizaki.com Modular Crescent Cuber Serenity Series Model KMS-1230MLH Including Condensing Unit Model SRK-13H INSTRUCTION MANUAL ™ Issued: 1-29-2007...
  • Page 2 Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, write or send an e-mail message to the HOSHIZAKI Technical Support Department for assistance. HOSHIZAKI AMERICA, INC.
  • Page 3: Table Of Contents

    • Please review this manual. It should be read carefully before the icemaker is installed and operated. Only qualified service technicians should install, service and maintain the icemaker. This manual should be made available to the technician prior to installation, maintenance or service.
  • Page 4: Specifications

    ELECTRICAL POWER SUPPLIES BEFORE SERVICING UNIT. See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel. This icemaker is designed for connection to HOSHIZAKI CONDENSING UNIT, Model SRK-13H or SRK-13H3 only! CONNECTION TO ANOTHER CONDENSING UNIT WILL VOID WARRANTY.
  • Page 5: Condensing Unit Model Srk-13H

    208-230/60/1 (3 WIRE WITH NEUTRAL FOR 115V) 230V 10RLA 82.0LRA 115V 2.6FLA (total) 126W 115V 0.4A HI-467PSI LO-230PSI R-404A 16LBS. 5oz. FOR OUTDOOR USE Hoshizaki America, Inc. Peachtree City, GA www.hoshizaki.com LISTED REFRIGERANT CONDENSER 18Z6 SRK-13H 20 AMPS 20 AMPS...
  • Page 6: Condensing Unit Model Srk-13H3

    Note: We reserve the right to make changes in specifications and design without prior notice. 115V 2.6FLA (total) 126W 115V 0.4A Intentionally Left Blank FOR OUTDOOR USE MOTOR-COMPRESSOR THERMALLY PROTECTED Hoshizaki America, Inc. LISTED REFRIGERANT CONDENSER 18Z6 SRK-13H3 208-230/60/3 230V 7.5RLA 65.5LRA...
  • Page 7: Dimensions/Connections

    B. Dimensions/Connections KMS-1230MLH Unit: mm (inches)
  • Page 8: Condensing Unit Model Srk-13H/3

    Unit: mm (inches) 2. Condensing Unit Model SRK-13H/3 [b]SRC-13H/13H3...
  • Page 9: Installation And Operating Instructions

    • A dry and well ventilated area with 4" clearance in both front and rear for proper air circulation and ease of maintenance and/or service should they be required. See Fig. 1. • The icemaker must be coupled with the appropriate condensing unit as listed below. Icemaker KMS-130MLH IMPORTANT IMPORTANT IMPORTANT Hoshizaki Condensing Unit SRK-13H/3...
  • Page 10: Checks Before Installation

    3. This icemaker is designed for dispensers 30" wide or wider. If using a storage bin, the recommended storage bin is HOSHIZAKI ICE STORAGE BIN, Model B-500 series. 1) Unpack the icemaker. Remove all shipping cartons, tape and packing. If packing material is left in the icemaker, it will not work properly.
  • Page 11: Condensing Unit

    2. Condensing Unit 1) Unpack and remove all shipping cartons, tape and packing. ) See the nameplate on the condensing unit. Check that your voltage supplied corresponds with the voltage specified on the nameplate. Note: Power to the icemaker is supplied by the condensing unit. Electrical connections must be installed in accordance with applicable national, state and local regulations.
  • Page 12: Installation Of The Icemaker

    D. Installation of the Icemaker Before operating the icemaker, the bin control must be installed correctly. Failure to properly install the bin control could result in ice backup and unit damage. 1. Setup 1) Unpack the dispenser or storage bin. If using a storage bin, attach the four adjustable legs provided (bin accessory) to the bottom of the storage bin.
  • Page 13 4) Remove the float connection hose from the plastic pipe. 5) Remove the tank drain hose from the tank. Although the tank can be removed at this point, do not remove it yet because the bin control is taped to the tank. Float Connection Hose The bin control lead is routed through the back of the icemaker.
  • Page 14 If a gap is left between the bin control and the wall of the dispenser, ice may get between them and damage the bin control. Therefore, make sure there is no gap. 1) Make sure the bin control is flush with the dispenser or storage bin wall, then tighten the  thumbscrews.
  • Page 15: Installation Of The Condensing Unit

    See "F. Electrical Connection." M8x16mm Bolt 2. Line Set • Precharged tubing kits, available as optional equipment from HOSHIZAKI AMERICA, are recommended. Field fabricated line sets are allowed, see instructions below. • The maximum line length is 55 feet.
  • Page 16 Factory Line Set Installation 1) Route the factory line set from the condensing unit to the icemaker. Factory fabricated line sets are precharged and do not need to be evacuated. ) Attach the two refrigerant lines to the male couplings on the remote condensing unit first and then at the icemaker.
  • Page 17: Electrical Connection

    F. Electrical Connection 1. Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided with the pig tail leads in the condensing unit junction box. . Electrical connections must meet national, state and local electrical code requirements.
  • Page 18: Icemaker

    3) Attach the harness wires to the correct location on the condensing unit's terminal board. Use the wiring label as a reference. 4) Replace the control box cover and panels in their correct positions. 5) Route the wire harness to connect the condensing unit's control box to the icemaker's control box.
  • Page 19 KMS-1230MLH Water Supply Inlet 1/" FPT Drain Outlet 3/4" FPT Condensate Drain 5/8" OD Pipe Fig. 9 Shut-Off Valve Drain Valve Bin Drain Outlet 3/4" FPT Separate piping to approved drain. Leave a two-inch (5 cm) vertical air gap between the end of each pipe and the drain.
  • Page 20: Final Checklist

    H. Final Checklist 1) Is the icemaker level? ) Are all components, fasteners and thumbscrews securely in place? 3) Is there at least 4" minimum clearance around the condensing unit? 4) Have all shipping cartons, tape and packing been removed from the icemaker and condensing unit? Are the cube guides and tank separator in their correct positions? 5) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (7°C to 38°C) all year around?
  • Page 21: Startup

    I. Startup 1. Electrical power must be on at the condensing unit for a minimum of 4 hours prior to start up to prevent compressor damage. . All parts are factory-adjusted. Improper adjustments may result in failure. 3. If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
  • Page 22: Cleaning And Maintenance Instructions

    1. Cleaning Procedure 1) Dilute  fl. oz. (650 ml) of the recommended cleaner Hoshizaki "Scale Away" or "LIME-A-WAY" (Economics Laboratory, Inc.) with 4 gal. (15 l) of warm water. ) Remove all ice from the evaporator and the dispenser or storage bin unit.
  • Page 23 9) Remove the insulation panel by removing the thumbscrews, then pour the cleaning solution into the water tank. 10) Move the service switch to the "WASH" position. 11) Replace the insulation panel and the front panel in their correct positions. 1) Turn on the power supply and start the washing process.
  • Page 24: Sanitizing Procedure - Following Cleaning Procedure

    2. Sanitizing Procedure - Following Cleaning Procedure 1) Dilute a 5.5% sodium hypochlorite solution (chlorine bleach) with water. (Add  fl. oz. (60 ml) of sanitizer to 4 gal. (15 l) of water). ) Remove the insulation panel, if it is in its normal position. 3) Pour the sanitizing solution into the water tank.
  • Page 25: Preparing The Icemaker For Long Storage

    C. Preparing the Icemaker for Long Storage When the icemaker is not used for two or three days under normal conditions, it is sufficient to only move the control switch to the "OFF" position. When storing the icemaker for extended time or in sub-freezing temperatures, turn the water off and drain out all water from the water lines and remove the ice from the dispenser or storage bin.
  • Page 26 16) Disconnect the float switch vent hose from the drain hose tee. Move the service switch to the "DRAIN" position and the control switch to the "SERVICE" position. 17) From the tee on the drain hose, blow the drain water valve out using compressed air or carbon dioxide.
  • Page 27 HOSHIZAKI AMERICA, INC. 618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A1YA10A...