Ice Machine
The icemaker must be cleaned & sanitized at least once a year.
Cleaning Prep:
1
Remove the Front Panel, move the
OFF. After 3 min., move the
replace the Front Panel.
2
After 3 min., remove the Front Panel, move the
control switch
to OFF. This removes the cubes from
the evaporator.
3
Remove all ice from the dispenser unit/ice storage bin
ATTENTION! IF ON DISPENSER, turn off the dispenser
power supply after dispensing all the ice.
Cleaning:
Top
Left
Side
Water Tank
4
Remove the Front Panel, move the
DRAIN. Move
control switch
the Front Panel.
5
After 2 minutes, remove the Front Panel, move the
control switch
to OFF.
6
Dilute Hoshizaki Scale Away with warm water (see Table below).
Remove the Front, Apron, Top, Left, & Left Insulation Panels
and pour cleaning solution into the water tank.
KMS-1122MLH(3)
Scale Away
27 fl. oz (800 ml)
Warm Water
5 gal. (19 l)
#51008 | 9.15.2016
Page 20
Cleaning & Sanitizing
control switch
to
control switch
to ICE, then
.
Service Switch
Control Switch
Front of icemaker
Drain Plug
service switch
to
to SERVICE. Replace
 continued on the back...
Tech Support: 1.800.233.1940
KMS-1122MLH(3)
unattended when panels are off
3
min.
AMMONIA
3
min.
Cleaners
Sanitizing:
 Dilute 5.25% chlorine
bleach* with warm water
(see Table below)
KMS-1122MLH(3)
Bleach
Warm Water
 Remove the front, apron,
top, left, & left insulation
panels
 Pour the sanitizing solution
into the water tank
 Replace all the panels, except
the front panel
 Move
WASH and
SERVICE, replace the front
panel
 After 15 minutes, remove
front panel
 Move
replace the front panel
After 2 min.
 After 2 minutes, remove
front panel
 Move
ATTENTION!
Do not leave icemaker
15
2.5 fl. oz (74 ml)
5 gal. (19 l)
* Use bleach without additives.
16
17
service switch
to
control switch
to
18
service switch
to DRAIN,
19
control switch
to OFF