Locate the Reed Switch (52) and the Magnet (51)
on the left side of the Pulley (50). Turn the Pulley
until the Magnet is aligned with the Reed Switch.
Make sure that the gap between the Magnet and
the Reed Switch is about 1/8 in. (3 mm). If nec-
essary, loosen the #8 x 3/4" Tek Screw (13), move
the Reed Switch slightly, and then retighten the
Screw. Reattach the Motor Hood (not shown) with
the #8 x 3/4" Hood Screws (not shown) and run the
treadmill for a few minutes to check for a correct
speed reading.
Top
View
52
13
SYMPTOM: The incline of the treadmill does not
change correctly
a. Hold down the Stop button and the Quick Speed
increase button, insert the key into the console,
and then release the Stop button and the Quick
Speed increase button. Press the Stop button
and then press the Quick Incline increase or
decrease button. The treadmill will automatically
rise to the maximum incline level and then return to
the minimum level. This will recalibrate the incline
system. If the incline does not begin calibrating,
press the Stop button again, and then press the
Incline increase or decrease button again. When
the incline is calibrated, remove the key from the
console.
SYMPTOM: The walking belt slows when walked on
a. If an extension cord is needed, use only a 3-con-
b. If the walking belt is overtightened, treadmill per-
50
51
3 mm
c. Your treadmill features a walking belt coated with
d. If the walking belt still slows when walked on, see
27
ductor, 14-gauge (1 mm
2
than 5 ft. (1.5 m).
formance may decrease and the walking belt may
become damaged. Remove the key and UNPLUG
THE POWER CORD. Using the hex key, turn both
idler roller screws counterclockwise, 1/4 of a turn.
When the walking belt is properly tightened, you
should be able to lift each edge of the walking belt
2 to 3 in. (5 to 7 cm) off the walking platform. Be
careful to keep the walking belt centered. Then,
plug in the power cord, insert the key, and run the
treadmill for a few minutes. Repeat until the walk-
ing belt is properly tightened.
b
5–7 cm
Idler Roller Screws
high-performance lubricant. IMPORTANT: Never
apply silicone spray or other substances to
the walking belt or the walking platform unless
instructed to do so by an authorized service
representative. Such substances may deterio-
rate the walking belt and cause excessive wear.
If you suspect that the walking belt needs more
lubricant, see the front cover of this manual.
the front cover of this manual.