SYMPTOM
Oven fan will not run
No control box cooling
No automatic control box
cooling
Oven will not heat
Impinger II – Advantage Digital Express Service Manual - Domestic

TROUBLESHOOTING GUIDE

MODEL 1116-080-A
MODEL 1116-080-A1
MODEL 1117-080-A
MODEL 1117-080-A1
POSSIBLE CAUSE
Incoming power supply
Fuse, 10 Amp
Fuse holder
Hi-limit thermostat,
control box
Switch, main power
Main fan motor
Capacitor
Incoming power
Switch, main power
Cooling fan
Incoming power supply
Cooling fan thermostat
Cooling fan
Gas supply
Manual gas shut off valve.
Main fan
Centrifugal switch of main fan
motor

GAS OVENS

NAT. GAS
120VAC
NAT. GAS
120VAC
LP GAS
120VAC
LP GAS
120VAC
EVALUATION
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if needed.
Check, replace if necessary.
Check, replace if necessary.
Check for voltage on both sides of switch. Terminals
are normally closed. If open, reset and test oven for
proper operation. If thermostat will not hold, and
control box temperature is not exceeding 140°F
(60°C), replace thermostat.
Check continuity between switch terminals. Replace
switch as needed.
Check for 120VAC at motor. If no voltage is present,
trace wiring back to main power switch.
WITH POWER OFF: Check for opens, shorts or
grounds. Turn fan blade to check for locked rotor.
Check for shorts or grounds.
WARNING: Capacitor has a stored charge,
discharge before testing.
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if needed.
Check continuity between switch terminals. Replace
switch as needed.
Check for 120VAC at cooling fan. If no voltage is
present, trace wiring back to power switch. If voltage
is present, and motor does not run, check for opens,
shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if needed.
Check the cooling fan thermostat. (Thermostat
closes at 120°F and opens at 100°F). With the
cooling fan thermostat pre-heated, check for
continuity. If switch is open, replace cooling fan
thermostat.
Check for 120VAC at cooling fan. If no voltage is
present, trace wiring back to cooling fan thermostat.
If voltage is present, and motor does not run, check
for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Check for adequate gas supply to oven.
Check to see that the manual gas shut off valve is
open. Also check flexible gas line connection for any
damage.
If not operating, refer to "Oven fan will not run".
Check for 120VAC at wire #5 (input to centrifugal
switch, located at 6-pin connector in raceway near
60 HZ.
60 HZ.
60 HZ.
60 HZ.
11