Magnum Ds80F Chassis; Magnum Ds80C Chassis - GarrettCom DS80C Installation And User Manual

Magnum personal hubs installation and user guide ds80f, ds80c
Table of Contents

Advertisement

Magnum DS80F & DS80C Dual-speed Stackable Hubs
2.2.1
Magnum DS80F chassis with fiber ST or SC (mm or sgl. mode) connector
12V, 1.5Amps
Magnum DS80 Dual Speed
Speed
Power
Link/Act
Error
F/H
GARRETT
PORTS
1SW
2SW
UPLINK
Tx
Rx
UPLINK
1SW
=
X
F
H
2SW
Fiber ST above, fiber SC at right
The Magnum DS80F chassis
houses one main PC board. The power supply unit is external. The front side of the chassis has
eight RJ-45 twisted-pair ports and one 100Mbps fiber port. Port #2SW always supports fiber
ports only and the RJ-45 connector is inoperative at all times. LEDs to indicate operating status
of all ports are mounted on the top. There are power (PWR) and ERROR (self-test at power up
failed) indicators for the unit. For each port, there are Link and Activity (LINK/ACT) LEDs
indicating traffic, and speed (ON for
100Mbps). Switched ports 1SW and 2SW
have full-half (F-H) duplex indicators.
The DC power plug connector or
"jack" is in the left rear of the chassis.
The external power supply is 5VDC at either 95 - 125vac at 60 Hz for "-d" models or 120-
250vac at 50Hz for "-i" models that have IEC power cable connector in the external power
supply housing.
2.2.2
Magnum DS80C chassis with all RJ-45 Copper ports
5VDC, 2Amps
Magnum DS80 Dual Speed
Speed
Power
Link/Act
Error
F/H
GARRETT
PORTS
1SW
Tx
Rx
UPLINK
1SW
UPLINK
=
X
F
H
2SW
with selectable Fullfixed- and Auto-negotiation (FF-A) capability. See section 4.4.
LEDs to indicate operating status of all ports are mounted on the top. There are power
(PWR) and ERROR (self-test at power up failed) indicators for the unit. For each port, there are
Link and Activity (LINK/ACT) LEDs indicating traffic, and speed (ON for 100Mbps). Switched
ports 1SW and 2SW have full/half (F/H ON for full duplex) duplex indicators.
www GarrettCom com
.
Personal Hub
3
4
5
6
7
8
3
4
5
6
7
8
Personal Hub
2SW
3
4
5
6
7
8
3
4
5
6
7
8
.
Installation and User Guide (12/01)
12V, 1.5Amps
Magnum DS80 Dual Speed
Power
Speed
Link/Act
Error
F/H
GARRETT
PORTS
1SW
2SW
UPLINK
Tx
Rx
1SW
UPLINK
F
H
=
X
F
H
2SW
PORTS
1SW
2SW
3
4
Personal Hub
Magnum DS80F Dual Speed
Rear View Magnum DS80-Series
The Magnum DS80C chassis
houses one main PC board. The power
supply unit is external. The front side of the
chassis has eight RJ-45 twisted-pair ports.
The 1SW and 2SW ports are switched ports
6
Personal Hub
3
4
5
6
7
8
3
4
5
6
7
8
GARRETT
5
6
7
8
F/H
Power
Link/Act
Error
Speed
12V, 1.5Amps
DC 12V

Advertisement

Table of Contents
loading

Table of Contents

Save PDF