Whirlpool CGW9100VQ0 Installation Manual page 8

Commercial dryer- gas or electric
Table of Contents

Advertisement

Available languages

Available languages

If connecting
by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
[]
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying
wires must be insulated.
[]
10-gauge solid copper wire (do not use aluminum).
[]
At least 5 ft (1.52 m) long.
GROUNDING
INSTRUCTIONS
m For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
m For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding
terminal or lead on
the dryer.
WARNING:
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
Electrical
Shock Hazard
Plug into a grounded
4 prong outlet,
Failure to do so can result in death or electrical shock.
[]
To supply the required 4 wire, single phase, 120/240 volt, 60
Hz., AC only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended.
Connect to an individual branch
circuit.
[]
This dryer is equipped with a CSA international Certified
Power Cord intended to be plugged into a standard 14-30R
walt receptacle. The cord is 5 ft (1.52 m) in length. Be sure
watt receptacle is within reach of dryer's final location.
[]
4-wire receptacle(14-30R)
Do not use an extension cord.
If you are using a replacement power supply cord, it is
recommended that you use Power Supply Cord Replacement
Part Number 9831317. For further information, please
reference the service numbers located in the "Assistance
or Service" section.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS
It is your responsibility
[]
[]
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance
with the Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association,
178 Rexdate Blvd., Toronto, ON M9W 1R3
CANADA.

Advertisement

Table of Contents
loading

Table of Contents