Use of this POL transport plug (A)
(plastic part with external threads)
will defeat safety feature of valve.
5. Hold regulator, insert nipple (B) into LP tank valve.
Handtighten coupling nut, holding regulator in a
straight line (C) with LP tank valve so as not to cross
thread the connection.
Nipple hasto be
centeredinto the
LPbankvalve
Hold couplingnut and regulatoras
shownfor properconnection to LP
tankvalve.
WARNING
Do not use grill until leak checked.
If leak is detected at any time, STOP and call the
Fire Department.
• If you cannot stop a gas leak, immediately close LP
tank valve and call LP gas supplier or your fire
department!
Leak
Testing
Valves,
Hoses
and Regulator
1. Turn all grill control knobs to OFF.
2. Be sure regulatoris tightlyconnectedto LP tank.
3. Completely open LP tank valve byturninghand wheel
counterclockwise.If you hear a rushing sound, turngas off
immediately.There is a major leak at the connection.
Correct before proceeding.
4. Brush soapy solutiononto followingconnections:
SideburnerHose.
6. Turn the couplingnut clockwiseto tighten to a full solid stop.
The regulatorwill seal on the back-check feature in LP tank
valve, resulting in some resistance. An additional one-half
to three quarters turn is required to complete
connection. Tighten by hand only - do not use tools.
NOTE: If you cannot completeconnection, disconnect
regulator and repeat steps 5 and 6 If you are still unable to
complete the connection, do not use this regulator!
WARNING
Do not insert any foreign objects into the valve
outlet. You may damage the valve and cause a
leak. Leaking propane may result in explosion,
fire, severe personal injury, or death.
Never attempt to attach this grill to the self-
contained LP gas system of a camper trailer or
motor home.
SideburnerValve
Manifold behind
control panel
Hose connection at manifold
Never remove opening
at end of valve
5. "If growing" bubblesappear, there is a leak. Close LP tank
valve immediatelyand retightenconnections.If leaks
cannot be stopped "do not try to repair" call for
replacementparts. To order new parts call Sears
PartsDirect sM at 1-800-366-PART (7278).
6. Always close LP tankvalve after performing leak test by
turning hand wheel clockwise.