Gas Supply; Natural Gas - DeLonghi DE 91 GW Installation And Service Instructions Use And Care Instructions

Table of Contents

Advertisement

GAS SUPPLY:

The connection must be executed by an authorised person according to the rele-
vant standards.
Before connecting the appliance to the gas main, mount the brass conical adaptor
onto the gas inlet pipe, upon which the gasket has been placed (figures 10-11).
Conical adaptor and gasket are supplied with the appliance (packed with conver-
sion kit for use with Natural gas or ULPG).
This appliance is suitable for use with Natural Gas or ULPG. (Check the "gas type"
sticker attached to the appliance).
For Natural Gas models the gas supply is connected to the pressure regulator
which is supplied with the appliance (fig. 11). Adjust the regulator to obtain a test
point pressure of 1 kPa with the two semi-rapid (SR) burners operating at the max-
imum.
For ULPG models the gas supply is connected to the test point adaptor which is
supplied with the appliance (fig. 10) and ensure that the supply pressure is regu-
lated to 2.75 kPa.
The connection must be made at the rear of appliance (left or right); the pipe do
not cross the cooker.
The inlet not used must be closed off with the cap and sealing gasket supplied.
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig. 13)
Figure 10
Gas connection for
ULPG
Test
point
12
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Test point adaptor
Figure 11
Gas connection for

NATURAL GAS

Test
point
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator