Setup; Ac Power; Fuse Replacement - Chauvet Mini Kinta User Manual

Hide thumbs Also See for Mini Kinta:
Table of Contents

Advertisement

3. S
ETUP

AC Power

Fuse
Replacement
Mini Kinta™ User Manual (Rev. 2)
The Mini Kinta™ has an auto-ranging power supply and it can work with an input voltage
range of 100~240 VAC, 50/60 Hz.
To determine the product's power requirements (circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product's back panel, or
refer to the product's specifications chart. The listed current rating indicates the
product's average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0~100% switch.
Disconnect the product from power before replacing the fuse.
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.
Pry the fuse holder out of the housing.
4.
Remove the blown fuse from the holder.
5.
Replace with a fuse of the exact same type and rating.
6.
Insert the fuse holder back in place and reconnect power.
Spare fuse holder
(inside safety cap)
A spare fuse is not included; however, the safety cap has room for a spare.
Always replace a blown fuse with the same type and rating.
Installed fuse
(held by plastic clip)
Safety cap