Brocade Communications Systems BR-1010 Administrator's Manual page 194

Supporting cna and supporting hba models
Table of Contents

Advertisement

B
fcdiag
Examples
bcu fcdiag --fctraceroute 2/0 50:05:07:63:04:13:46:eb
Error: Reject from attached fabric
bcu fcdiag --fctraceroute 2/0 50:05:07:63:04:13:46:eb
FC Traceroute completed successfully. Path Info:
Switch WWN
10:00:08:00:88:03:31:8b
10:00:08:00:88:03:31:8b
bcu fcdiag --fctraceroute 2/0 50:05:07:63:04:13:46:e1
FC Traceroute Failed. Reason : Destination Port not in Fabric
bcu fcdiag --fcecho 2/0 50:05:07:63:04:13:46:eb
FC ECHO completed successfully
See Also
"diag"
176
Switch Domain ID
Ingress Port #
127
5
127
11
Egress Port #
11
5
Brocade Adapters Administrator's Guide