Dimmer Curves; Control Panel Lock; Program Upload; Reset - Chauvet ColorDash Batten-Tri User Manual

Table of Contents

Advertisement

Operation

Dimmer Curves

Control Panel Lock

Program Upload

Reset

Default Values
-10-
Continued from previous page
This setting determines the output of the COLORdash™ Batten-Tri based on the
position of the Red, Green, Blue, and Dimmer faders.
1) Go to SETTINGS.
2) Select DIMMER.
3) Select a dimmer curve (OFF, DIM1, DIM2, DIM3, or DIM4).
·
When Dim is set to "OFF", the output is proportional (linear) to the Dimmer
and RGB channel values.
·
When Dim is set to "DIM1" through "DIM4", the output follows the Dimmer and
RGB channel values based on the corresponding dimmer curve, being DIM1
the fastest and DIM4 the slowest.
This setting allows the user to activate or disable the control panel lock, which keeps
non-authorized personnel from changing the fixture's settings.
1) Go to KEYLOCK.
2) Select ON or OFF.
When the control panel lock is active, the fixture will prompt the user to enter the
password after 30 seconds of control panel inactivity or after turning on the
fixture.
After being prompted to enter the password:
1)
Press <UP>, <DOWN>, <UP>, <DOWN>, and <ENTER>
This option allows the user to copy the custom programs of one COLORdash™ Batten-
Tri fixture onto other COLORdash™ Batten-Tri fixtures by using the Master/Slave
method
1) Configure and connect the fixtures in a Master/Slave arrangement, where the
master unit has the custom programs you want to transfer onto the slave units.
2) At the master unit, go to SETTINGS.
3) Select UPLOAD.
4) When prompted, enter the master access password as shown in Control Panel
Lock.
5) When SEND shows, press <ENTER> to start the upload.
6) Wait for the upload process to finish before disconnecting the fixtures.
·
During and after the upload, the master and slave units will visually indicate
the status of the process, as follows:
·
Yellow means that the upload is running.
·
Red means that the upload failed due to an error.
·
Green means that the upload completed successfully.
This setting allows the user to reset the COLORdash™ Batten-Tri fixture to its default
values, including the custom programs.
1) Go to SETTINGS.
2) Select RESET.
3) When prompted, enter the master access password as shown in Control Panel
Lock.
4) Wait for the reset process to finish.
Parameter
Default Value
STATIC
ADDRESS
RUN
PERSON
ID
ID ON/OFF
Continues on the next page
Parameter
000
DIMMER
001
COLOR
DMX
EDIT
TOUR
FANS
001
KEYLOCK
ON
COLORdash™ Batten-Tri User Manual Rev. 02a
Default Value
DIM4
OFF
000
AUTO
OFF

Hide quick links: