GCL-MJ | MEDIUM-DUTY JACKSHAFT OPERATOR
Commercial Steel Insulated & Non-Insulated
Door Series
216
216
Ins.
Flush
Max
Door
16GA.
Model
16GA.
Wt.
Ins.
(lbs.)
170
120
1/2 HP
620
Door Series
16GA.
18GA.
Max
Door
Model
Wt.
197
246
(lbs.)
1/2 HP
580
Notes:
1. Max Door Weight and not the square footage, is the critical factor in selecting the proper operator.
2. Max Door Height 16'
3. For "Commercial Steel Insulated" category, various "backer" options are available. The chart above is based in all cases on the thickest backer available.
4. "PU-FIP" stands for "polyurethane, foamed-in-place." If no notation is present, insulation is "polystyrene laid-in-place."
Construction
• Motor
1/2 HP, AC capacitor start/run motor. Motor replaceable without
changing limits.
• Brake
AC solenoid-actuated band brake.
• Drive
Primary — TensiBelt
auto tensioning Poly-V J belt.
Secondary — chain and sprocket reduction.
• Friction Clutch
Adjustable clutch to help protect against door and
operator damage.
• Precision Radial Ball Bearings
Included in critical areas throughout the powertrain.
• Emergency Manual Operation
Pull-cord disconnect disengages drive allowing door to be moved
manually while maintaining limits.
• Pre-wired to accept:
- Monitored entrapment device such as photo eyes.
- Single or 3-button control stations.
- External interlock switches.
AMPERAGE RATING 1Ø 60Hz
Hp
1/2
8
7
6
NOTES: (UNLESS OTHERWISE SPECIFIED)
15
F
10
16 "
3
3
4 "
15
3
16 "
E
5
17"
19
8 "
D
C
B
A
THIRD ANGLE PROJECTION
8
7
6
MAX DOOR SIZE (SQ*FT) - SECTIONAL
220
2415
220
2415
Ins.
Ins.
Ribbed
20GA.
20GA.
24GA.
24GA.
Steel
Ins.
Ins.
230
160
270
200
MAX DOOR SIZE (SQ*FT) - ROLLING
Steel Non-Insulated
20GA.
22GA.
24GA.
246
338
394
115V
230V
6.5
3.1
5
4
3
7
7
9
16 "
13
8 "
9
5
16 "
6
8 "
8"
2"
5
19
8 "
1
18
2 "
3
3
6
4 "
7
16 "
MOUNTING DIMENSIONS
SECTIONAL WALL MOUNT
PLOTTED: 10/19/11
UNLESS OTHERWISE SPECIFIED
THE DRAWINGS AND ALL OTHER
INFORMATION CONTAINED HEREIN ARE
INTERPRET DIMS & TOLS
THE CONFIDENTIAL PROPRIETARY
PER ASME Y14.5M
PROPERTY OF OVERHEAD DOOR
CORPORATION, INCLUDING ITS
AFFILIATED SUBSIDIARIES AND
ALL DIMS ARE IN
AFFILIATES. THIS DRAWING
INCHES
INFORMATION, IN WHOLE OR IN PART,
www.GenieCompany.com/commercial
MAY NOT BE COPIED IN ANY MANNER OR
DO NOT SCALE
DISCLOSED TO ANYONE WITHOUT PRIOR
WRITTEN CONSENT OF OVERHEAD DOOR
CORPORATION. DISCLOSURE OF ANY
DIMS CIRCLED WITH
DRAWING OR INFORMATION IS INTENDED
SYMBOL '
' ARE CRITICAL
NOT TO AND SHALL NOT OPERATE AS A
TO QUALITY DESIGN
LICENSE OR AUTHORIZATION TO USE IT
FEATURES & MUST MEET
FOR ANY PURPOSE WITHOUT SPECIFIC
APPLICABLE IN-PROCESS
WRITTEN CONSENT OF OVERHEAD DOOR
CORPORATION.
INSPECTION STANDARDS.
5
4
3
©2012 The Genie Company
|
GCL-MJss
Thermospan
2411
2411
125
150
Ins.
Nominal
Nominal
PU-FIP
24GA.
PU-FIP
24GA.
1.38"
Ins.
300
256
256
256
Steel Insulated
26GA.
18GA.
20GA.
22GA.
394
148
148
197
Accessories and Options
• Timer to Close Module
Timed close set via the LCD display from 2 seconds up to 5 minutes.
Includes pre-close warning contacts, timer hold input, auxiliary open
input, normally closed safety input, and monitored edge input.
• Auxiliary Output Module
Provides relay contacts at the open, close, and mid-stop limits. Contacts
for 5-minute lamp, and "ADA" contacts set via LCD display to warn during
opening, closing or both.
• 315Mhz Receiver Module
IntelliCode
I radio receiver that is 315Mhz and capable of storing 50
®
single-button and/or 50 open-close-stop transmitters with the ability to
add and/or delete transmitters individually, identify and store activating
transmitter ID(s).
• UL325-2010 Approved Reversing Devices
The installation of a monitored external entrapment device is required
for momentary contact close operation on all commercial door operators.
Only the following devices, when purchased through Genie, are UL-
Approved for use to meet this requirement:
• Safe-T-Beam
P/N 38176R.S
• Impact-protected Commercial Photoeye Kit P/N OPAKPE.S
• MillerEdge ME/MT/CPT (DC or T3) 2-wire edge sensor. Must be
used with TCM (OPABTCGX.S) or Interface Module (OPAKMEIGX.S).
2
1
• Nema 4 Photoeyes P/N OPAKPEN4GX.S
REVISIONS
ER
REV
DESCRIPTION
DATE
APPROVAL
501348
-
ORIGINAL ISSUE
— Default device when operator is ordered.
1
F
7
4
8 "
E
D
12"
C
B
P/N 112213-0001
APPROVALS
A SUBSIDIARY OF OVERHEAD
DATE
DOOR CORPORATION
TOLERANCES:
DRAWN
WDR
10/19/2011
ALLIANCE, OHIO
.X
= ±.1
CHECKED
WDR
11/9/11
A
.XX = ±.01
DESCRIPTION
APPROVED
.XXX = ±.005
MS
11/10/11
GMXJ TECHNICAL INFO
ANGULAR = ±1
MATERIAL
|
800.843.4084
HOLES:
< Ø.251 = .003
FINISH
SIZE
DWG NO.
Ø.251-Ø.500 = .003
D
112213
> Ø.500 = .003
ALL GEOMETRY GOVERNED BY 3D CAD DATABASE
:
112213-GMXJ-SECT
SCALE 1:2
SHEET 1 OF 2
2
1
ThermoMark
®
200
200-20
5150
5200
Insulated
Insulated
PU-FIP
PU-FIP
PU-FIP
PU-FIP
2"
Raised
Raised
2"
20GA.
Panel
Panel
Ext.
1.38"
240
160
256
256
Counter Doors
Grilles
STL/SST
STL/SST
Aluminum
Aluminum
126
126
300
200
®
Photoeye Kit with adjustable bracket
1
Aluminum
451
452
1/4" or
1/8"
1/2"
Glass
Glass
1.38"
2"
1.38"
210
144
Sheet Door