To set the clock:
1. Push both the "SELECT" and
"RESET" buttons for at least two
seconds.
2. When the hour digits start flashing,
push the "RESET" button to set
the hours.
3. Push the "SELECT" button to
change the minutes.
4. When the minute digits start flash-
ing, push the "RESET" button to
set the minutes.
5. Push the "SELECT" button to start
the clock.
NOTE:
_
After setting the clock, be sure to push
the "SELECT" button before turning the
key to "OFF", otherwise the clock will
not be set.
_
INSTRUMENT AND CONTROL FUNCTIONS

Self-diagnosis devices

This model is equipped with a self-di-
agnosis device for the following electri-
cal circuits:
G
throttle position sensor
G
speed sensor
G
EXUP system
G
overturn switch
If any of those circuits are defective,
the tachometer will repeatedly display
the following error code:
CB-23E
Circuit-specific
0
r/min for
number of r/min
3 seconds
for 2.5 seconds
(See the table
below.)
Use the chart below to identify the
faulty electrical circuit.
CB-29E
Specific r/min
Faulty electrical circuit
3,000 r/min
Throttle position sensor
4,000 r/min
Speed sensor
7,000 r/min
EXUP system
9,000 r/min
Overturn switch
3-4
EAU04049*
If the tachometer displays such an er-
ror code, note the circuit-specific num-
ber of r/min, and then have a Yamaha
dealer check the motorcycle.
CAUTION:
_
When the tachometer displays an
error code, the motorcycle should
be checked as soon as possible in
order to avoid engine damage.
_
Current
engine
speed for
3 seconds
EC000004
3