Drainkit Installationinstructions; Internal Drain Installation; External Drain Installation - Whirlpool Packaged Terminal Air Conditioner Installation Manual

Packaged terminal air conditioner (ptac)/ packaged terminal pump (pthp) and accessory
Table of Contents

Advertisement

265 Volt PTAC/PTHP
All 265 volt PTAC/PTHPs are equipped with pigtail leads for field
wiring.
IMPORTANT:
Use copper conductors
only.
Wire sizes are per NEC.
Use on individual branch circuit only.
Use overcurrent
protection indicated on PTAC/PTHP's rating
plate.
PTAC/PTHP must be grounded to branch circuit.
Check local codes.
Electrical
Shock
Hazard
Electrically
ground
PTAC/PTHP.
Connect
ground
wire to green
pigtail
lead.
Use copper
wire for supply
connection.
Correct
wire
gauge
is shown
in the chart
below.
Failure
to fo!low
these
instructions
can
result
in
death or electrical
shock.
Rating
Plate Ampacity
Less than
15
16 - 20
21 - 30
AWG
14
12
10
DRAINKIT INSTALLATIONINSTRUCTIONS
Unpack and dispose of packaging materials.
The drain kit accessory contains 10 complete drain kits.
Locate the drain kit in the primary area for best drainage.
Maintain at least 1/2in. (1.27 cm) distance from the embossed
area. If the primary area cannot be used, locate the drain kit in
the secondary area and cut away the foam insulation to allow
access to the drain. Do not locate the drain kit within 3 in.
(7.6 cm) of the indoor side of the sleeve.
1
NOTES:
Determine whether the drain will be located on the exterior of the
wall, internally in the wall cavity or internally in the room.
Internal drain
Drain kit located inside the room will allow condensate to
drain to a field drain located inside the room.
Drain kit located inside the wall cavity will allow condensate
to drain to a field drain located inside the wall cavity.
External drain
Drain kit located outside will allow condensate to drain to a
field drain located outside or to drain away from the wall
sleeve.
When using an external drain system, select the drain hole on
the back of the wall sleeve which best meets your drainage
situation.
The cover plate and external drain tube assembly may be
placed on either side of the wall sleeve.
(7.6 cm)
1. Secondary area
2. Primary area - no foam insulation
3. If the drain must be located in the secondary area,
the foam insulation must be cut away and removed
to allow access to the drain.
4. Embossed area