1. Turn off all switches and unplug machine.
2. Unlatch and remove recovery tank.
3. Unfasten screws holding vacuum motor retainer to
vacuum motor housing
4. Lift vacuum motor from vacuum motor housing.
Locate the vacuum motor wires and disconnect at
the connector.
5. Remove vacuum motor.
6. Reverse process to install vacuum motor replace-
ment.
WARNING: The green ground wire must be attached for
safe operation. See wiring diagram.
AVERTISSEMENT: Le fil à la terre vert doit être attaché
pour un fonctionnement en toute sécurité. voir le schéma
de câblage.
Carbon
Brushes
If armature commutator is grooved, extremely pitted or not
concentric, the motor will need to be replaced or sent to a
qualified service center.
Important:
These brushes wear quicker as the length shortens due to
increased heat. Spring inside brush housing will damage
motor if brushes are allowed to wear away completely.
3
8
Periodically check the length of the carbon brushes. Replac
both carbon brushes when either is less than 3/8" (9.5mm)
long.