BEFORE CALLING FOR SERVICE
Check
the following
list to be sure a service
call is really necessary.
A quick
reference
to this manual
may
help you avoid an unneeded
service
call.
THE AIR CONDITIONER WILL NOT OPERATE
Check
if...
Wall ptug disconnected.
House fuse b!own or circuit breaker tripped.
Power is OFF.
Unit was turned off and then on toe quickly.
TEMP Control set warmer than room temperature.
Then...
Push plug firmly into wall outtet.
Replace fuse with time delay type or reset circuit breaker.
Push the power button.
Set unit off and wait 3 minutes before restarting.
Set TEMP Contro! to lower temperature.
AIR FROM UNIT DOES NOT FEEL COLD ENOUGH.
Check if...
Then...
FAN SPEEDset at LOW.
PushFAN SPEEDbuttonto set at HI.
TEMPControl may not be set correctly.
Set TEMPControlto iower temperature.
(TempCentreiset too warm)
Temperaturesensingtubetouchingevaporatorceil,
Straightentube awayfrom evaporatorcoii.
locatedbehindfront grille.
THEAIR CONDITIONER C OOLING, B UTROOM18TOOWARM- ICEFORMING ON COOLING COIL BEHIND FRONTGRILLE.
Check if...
Then...
Outdoortemperaturebelow7O°F(21°C).
To defrostthe coil,set the MODE to FAN.
Air filter may be dirty.
Ciean air filter.Referto Maintenancesectionof owner'smanual.
TEMPControlset too cold for night-timecooling.
Todefrost t hecoil,setthe MODEto FAN or "HighCool"withthe
TEMPcontrol t o hiqher t emperature.
THEAIRCONDITIONER C OOLING, B UTROOM 18TOOWARM.
Check if...
Then...
Dirtyair filter - air restricted.
Clean air filter.Referto Maintenancesectionof owner'smanual.
TEMPControlset too warm.
Set TEMP Controito lowertemperature.
Frontof unit is blockedbydrapes, blinds,furniture,etc.
Ciear blockagein frontof unit.
Air distributionis restricted.
Doors,windows,registers,etc.open. Coldair escapes.
Closedoors,windows,registers,etc.
Unitrecentlyturnedon in hot room.
Allowadditional timetoremove storedheat f romwalls, c eiling, f loor,andfurniture.
THE AIR CONDITIONER
TURNS
ON AND OFF RAPIDLY.
Check if...
Then...
I Outsidetemperatureis extremelyhot.
I Set FAN SPEEDon HI to bringair pastcoolingcoils faster.
I
NOISE WHEN
UNIT IS COOLING.
Check if...
Then...
Soundoffan hittingwaterfromthe moisture removal s ystem. This is normalwhen humidityis high.Closedoors,windows,andregisters.
Windowvibration- poor installation.
Referto nsta at on nstructonsor check w th nsta er.
WATER
DRIPPING
INSIDE
ROOM WHEN
UNIT 18 COOLING.
Check if...
Then...
The air conditioneris improperlyinstalled.
Tiltinstallationair
conditionerinstructionsSlightlYor
tOcheckthe
outsidewith
installer.t°
allowwaterdrainage.Referto
WATER
DRIPPING
OUTSIDE
WHEN
UNIT IS COOLING.
Check if...
Then...
The unitis removinglarge quantitiesof moisture
This is normalduringexcessivelyhumiddays.
from humid room.