Download Print this page

Technical Specifications - HP ProLiant DL560 Specification

Hide thumbs Also See for ProLiant DL560:

Advertisement

QuickSpecs

Technical Specifications

System Unit Rack
Chassis Footprint
(HxWxD)
Weight
Input Requirements
Max BTU Rating
Power Supply Output
Power (per power
supply)
Temperature Range
Relative Humidity
(non-condensing)
Maximum Wet Bulb
Temperature
Acoustic Noise
DA - 11595 Worldwide QuickSpecs — Version 46 — 12.16.2005
3.38 x 17.50 x 25.75 in (8.59 x 44.45 x 65.41 cm)
Maximum (2 Power
Supplies, 2 Hard Drives)
Minimum (No hard drives
installed, one power
supply)
Rated Input Voltage
Rated Input Frequency
Input Power
Rated Input Current
2375 BTU (550 Watts)
Rated Steady-State
Power
Maximum Peak Power
Operating
Non-operating
Shipping
Operating
Non-operating
101.7° F (38.7° C)
NOTE: Listed are the declared A-weighted sound power levels LWAd
and the declared average bystander position sound pressure levels
LpAm when operating in a 23° C ambient environment. Noise emissions
were measured in accordance with ECMA 74 and declared in
accordance with ECMA 109.
Idle (Fixed Disk Drives
Spinning)
L WAd (BELS)
L pAm (dBA)
NOTE: These values apply to 2U rack configuration. Configuration
tested included 2 processors, two 10, 000 rpm hard drive, 1 power
supplies, 1 power supply fan and 4 CPU fans.
HP ProLiant DL560
60 lb (27 kg)
35 lb (16 kg)
100 to 120 VAC/200 to 240 VAC
50 to 60 Hz
690W @ 115 VAC/675W @ 230 VAC
7A (100 VAC), 6A (115 VAC), 3A (230 VAC)
550W/550W (lowline/highline)
550W/550W (lowline/highline)
50° to 95° F (10° to 35° C)
-20° to 140° F (-29° to 60° C)
-22° to 122° F (-30° to 50° C)
10% to 70%
5% to 95%
6.0
46
Page 31

Advertisement

loading