1.2 Selecting Mounting
Location
The PG-1000 must be indoor on the horizon-
tal plane.
When selecting a mounting location, keep in
mind the following points:
• The ambient temperature must be between
-15 C and 55 C.
• Vibration at the mounting location should
be minimal.
• Install the sensor as far as possible from
power cable, ferrous materials.
• Install the sensor ship's center of gravity.
• Align the bow mark with the ship's bow on
the fore-and-aft-line.
1. Tentatively select the mounting location. Do
not fix it yet.
Ship's bow
Figure 1 PG-1000
2. Connect the PG-1000 to the battery as
shown in right.
2
Red
Figure 2 Battery connections to PG-1000
3. Turn the ship's mains switch on.
Bow mark
4. Confirm that the STATUS LED blinks.
BOW
12-24 VDC
+
-
NMEA
Å~
Sensor (top view)
Black
+
-
12-24 VDC
This sensor doesn't have power switch.
AUTO
TRUE
About two minutes later
: On
: Blinking
: Off
: Status depends on settings.
Figure 3 LEDs at power on
Two minutes later it will light. If STATUS
LED doesn't blink and then light, suspect
sensor error. Reset power.
AUTO
TRUE
: On
: Status depends on settings
: Off
Figure 4
AD10
Grounding
STATUS
CALIB
CALIB
STATUS
normal
error

Advertisement