Correcting Magnetic Anomalies; Controls And Indications; Turning The Power On/Off - Furuno PG-1000 Operator's Manual

Furuno integrated heading sensor operator's manual model pg-100
Hide thumbs Also See for PG-1000:
Table of Contents

Advertisement

2 CORRECTING MAGNETIC
ANOMALIES

2.1 Controls and Indications

On: Auto correction is on.
Off: Auto correction is off.
On: True heading is output.
Off: Magnetic heading is output.
Off: Normal
Blinking: Correcting
AUTO
TRUE
CALIBRATION
AUTO TRUE
INTEGRATED HEADING SENSOR
Selects output data format; magnetic or true
Turns on and off deviation corrections.
Figure 18 Front panel of PG-1000
8
the deviation.
(On installing.)
On: Normal
Off: Error
CALIB
STATUS
PG-1000
Corrects the heading.

2.2 Turning the Power On/Off

Note: You may leave port after the STATUS
LED begins lighting (not blinking).
Power to the sensor unit may be turned on or
off at the mains switchboard.
1. Turn the mains switch on.
STATUS LED blinks. About two minutes
later it lights. Bearing is now reliable.
AUTO
TRUE
AUTO
TRUE
: On
: Blinking
: Status depends on settings
: Off
Figure 19 LED state at power on
STATUS
CALIB
About two minutes later
CALIB
STATUS
normal
error

Advertisement

Table of Contents
loading

Table of Contents