Advertisement

5. Press the [AUTO] and [+] keys together
more than two seconds.
AUTO
TRUE
CALIBRATION
AUTO TRUE
INTEGRATED HEADING SENSOR
Figure 5 Key and LEDs
After the TRUE, CALIB and STATUS
LEDs light and AUTO LED blinks, rotate
the equipment 360º slowly, keeping it
uplight. If three LEDs are lighting, the
mounting location is suitable.
AUTO
TRUE
Figure 6
If one or more LED is off, the mounting
location is not suitable. Try to change the
location, and do step 5 again.
6. Press the [AUTO] and [TRUE] keys to-
gether to return to the normal mode. The
STATUS LED blinks while the sensor is be-
ing calibrated and lights steady when the
calibration is completed. Do not operate the
sensor while the LED is blinking; calibra-
tion will be incomplete.
CALIB
STATUS
PG-1000
CALIB
STATUS
: On
: Blinking

1.3 Mounting

1. Fix the sensor by using screws and washers
(supplied). The size of the fixing hole is ø
4.5 mm.
Ship's bow
fixing hole
This line should be at right
angles to the fore and aft line.
o All dimensions in mm.
o For added support, use nuts, bolts and
washers.
o Secure sufficient clearance around the
sensor for maintenance and checking.
Figure 7 Mounting the PG-1000
Note: Do not overtighten the screws or bolts;
the sensor may crack.
Bow mark
Material: Brass