View Screens 1 through 10: These menus provide an overview of the units current operating
parameters and the menu settings selected by the user or installer. Each View Screen is described in
the following tables. The default values are bolded and italicized.
The View Screens
View Screen 1
Alarm Input
Enable/Disable: 1 = Enabled, 0 = Disabled
Normally Open or Normally Closed: 0 = Open, C = Closed
Macro: Macro number if activated.

Alarm Action

Freeze: 1 = Freeze, 0 = No Freeze
Cameras: Primary camera in alarm and three associated cameras.
Relay: 1, 2, 1+2, or None.
Intrusion AND/OR: AND, OR
View Screen 2
Camera
Enable/Disable: 1 = Enabled, 0 = Disabled
Signal Gain: AGC setting from 1 through 100. 50
Covert Camera: Yes or No
Camera Title: Camera x, x=number
Videoloss Action
Relay 1: 1 = Enabled, 0 = Disabled
Relay 2: 1 = Enabled, 0 = Disabled
Buzzer: 1 = Enabled, 0 = Disabled
View Screen 3
Motion Detection
Enable/Disable: 1 = Enabled, 0 = Disabled
Activity or Intrusion Detection: I = Intrusion, A = Activity
Sensitivity: 1 through 10, 5
Relay Output: None, 1, 2, 1+2
Link to Event: Yes or No
Rejection Ratio: High, Medium, or Low
Target Size: 1 through 256
Alarm Camera: 1 through 4, 10 or 16
0150-0193G
64
DVMRe Triplex