Alarm Out - GE Calibur DSR-1000eZ User Manual

Single channel color digital video recorder
Table of Contents

Advertisement

Alarm In
An alarm condition can be activated by an Active Low TTL input
or by relay contact devices such as pressure pads, passive
infrareds, door switches, or other similar devices.
A c c e s s o r i e s P C B

Alarm Out

The Alarm output is activated when a teletext alarm is detected,
or while the Alarm Input is active. The Alarm output is only
active for the duration of the alarm event.
Record Start In
Record Start In will place the unit in Record mode when
activated. Compatible with the Disk End Out signal from a
second unit.
Alarm Record Reset
This feature is for future development, and has not yet been implemented.
Calibur DSR-1000eZ
Figure 1-4 Normally Open Relay Alarm Connection
A l a r m I n p u t
Pin 1
G r o u n d
Pin 7 or 10
N o r m a l l y O p e n
( C l o s e s D u r i n g A l a r m )
T y p i c a l A l a r m D e v i c e
R e f e r t o e a c h a l a r m d e v i c e s ' s
m a n u a l f o r s p e c i f i c w i r i n g d e t a i l s .
1-6
Input: Active Low TTL w/ pull-ups
or Normally Open Relay.
High: 5V (12V tolerant)
Low: Ground
Minimum Duration: 0.5 Seconds
Output: Active Low
High: 12V
Low: Ground
Current Out: 50mA Max
Short Circuit Protected.
Low for duration of alarm.
Input: Active Low TTL w/ pull-ups
or Normally Open Relay.
High: 5V (12V tolerant)
Low: Ground
Minimum Duration: 0.5 Seconds
0150-0238A