Sensor Setup - Furuno 1833 Operator's Manual

Furuno marine radar user manual
Hide thumbs Also See for 1833:
Table of Contents

Advertisement

5.9.2

Sensor setup

The SENSOR SETUP menu lets you further refine speed, water temperature
and depth data fed from the network sounder.
1. Show the sounder display, then press the [MENU] key.
2. Press the SOUNDER SYSTEM SETUP and SENSOR SETUP soft keys to
show the SENSOR SETUP menu. The current ship's speed, water
temperature, depth and speed of sound are shown at the bottom of the
menu.
3. Select item to adjust, then press the EDIT soft key.
4. Adjust the trackball upward or downward to set appropriate value.
Speed and temperature calibrations: Enter plus or minus value. For
example, if the water temperature readout is 77 F but the actual water
temperature is 75 F, enter –2( F).
Depth calibration: If you desire the depth readout to show the distance
between ship's draft and bottom (rather than transducer and bottom), set
ship's draft here. Enter a plus or minus value.
Acoustic speed calibration: Sets the speed of sound used by the network
sounder. Normally no adjustment is required, however if echoes are returning
too slow or too fast adjust the value as appropriate. This is only used if water
salinity is at an extreme level. Under normal circumstances, do not adjust.
Speed Calibration
Temperature Calibration
Depth Calibration
Acoustic Speed Calibration
5. Press the RETURN soft key followed by the [MENU] key.
SPEED CALIBRATION
+ 00%
TEMP CALIBRATION
+ 00 F
DEPTH CALIBRATION
+00ft
ASCTC SPD CALIBRATION
+ 000m/s
SPEED
12.3kt
DEPTH
125.0ft
Sensor setup menu
Sensor setup menu settings
Item
-50 -+50%
-40°F – +40°F
-15 - +90 ft
-500 - +500 m/s
5. CUSTOMIZING YOUR UNIT
SENSOR
SETUP
EDIT
RETURN
TEMP
78.8 F
ACSTC SPD
1500m/s
Settings
Default Setting
0 (no offset)
0 (no offset)
0 (no offset)
0 (no offset)
5-29