REMOVING THE BURNER ASSEMBLY,
FLAME SENSOR, AND HIGH-LIMIT THERMOSTAT
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the two hex-head screws from
the bottom flange of the toe panel. Pull the
panel out at the bottom, pull down, and
remove the panel.
Toe Panel
Toe Panel Screws

(GAS DRYERS ONLY)

4.
4-18
Burner Assembly
To remove the burner assembly:
a) Remove the two hex-head screws from
the burner support bracket, and pull the
bracket away from the burner assembly.
Screws
Burner Support