AND Weighing Indicator AD-4401 Instruction Manual page 86

Table of Contents

Advertisement

CALF-
Name
Standard Serial
Output; Output
12
When Weight Value
Is Overflowing or
Unstable
RS-232C/-422/-485
; Output When
13
Weight Value Is
Overflowing or
Unstable
14
Weighing Mode
15
Zero Input Voltage
Span Input Voltage
16
(Capacity to zero)
Weight against
17
Span Input Voltage
User's
Default
Parameter
1
1
3
0.000000
0.000000
2.200000
0.000000
3.200000
3.200000
0 to 800000
(decimal
16000
point
ignored)
Setting
0
Does not output when the weight value is overflowing
or unstable
1
0
Outputs even if the weight is overflowing or unstable
1
Does not output when the weight value is overflowing
0
or unstable.
Outputs even if the weight value is overflowing or
1
unstable
Normal batching
(Customer
1
programmed
control mode)
Loss-in-weight
(Customer
2
programmed
control mode)
Normal batching
(Built-in
3
automatic program
mode)
Loss-in-weight
(Built-in
4
automatic program
mode)
5
Check weighing 1
6
Check weighing 2
7
Check weighing 3
8
Check weighing 4
Input Voltage (mV/V) from the Load Cell at "Zero",
to
which is determined in "Zero Calibration" with weights.
Input Voltage (mV/V) from the Load Cell at "Span",
which means the difference between Capacity and
to
Zero. The voltage is determined in "Span Calibration"
with weights.
When "Digital-Calibration", calibration not using
weights, is performed, CALF-15 and CALF-16 also
have to be done.
This setting will be changed to Capacity (CAL-04) if
"CAL Set" is done.
84
Description
Batch
For the hopper
Weighing
scale use
Check-Wei
For the platform
ghing
scale use