Sanyo CG1411 Service Manual page 9

Gas heater air conditioner
Hide thumbs Also See for CG1411:
Table of Contents

Advertisement

2-2-2. Outdoor Unit (1)
Outdoor unit CG1411
Control PCB
Part No.
Controls
Control circuit fuse
Gas Connection
Employed gas
Gas connection
Compressor
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (ambient temp. 68°F (20°C))
Safety devices
Run capacitor
PTC starter
Crank case heater
Fan & Fan Motor
Type
Q'ty ... Dia. and length
Fan motor model ... Q'ty
No. of poles ... rpm (115V, High)
Nominal output
Coil resistance (ambient temp. 77°F (25°C))
Safety devices
Run capacitor
Heat Exchanger Coil
Coil
Rows
Fin pitch
Face area
External Finish
Type
Overload relay
Operating temp.
Open °F (°C)
Close °F (°C)
Operating amp (ambient temp. 77°F (25°C))
Part number
Resistance
Max voltage
inch. (mm)
Type
Operating temp.
Open °F (°C)
Close °F (°C)
inch (mm)
W
cc
µF
VAC
W
174 ± 27 (79 ± 15) Automatic reclosing
µF
VAC
Aluminum plate fin / Copper tube
2
2
ft
(m
)
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
5
CG1411
Microprocessor
115V 5A
Natural Gas (LP)
1/2 Female
Rotary (Hermetic)
C-1R71H2W
700
SUNISO 4GSD-T ... 370
C – R: 0.879
C – S: 3.609
External (OLR)
MRA98962-9200
275 ± 9 (135 ± 5)
156 ± 20 (69 ± 11)
Trip in 6 to 16 sec. at 34A
35
330
912X24E400XR20-PS2A
47
300
Propeller
1 ... 13-25/32 (ø 350)
SB6-11H1P ... 1
6 ... 600
10
BLU – BRN: 114.0 ± 7%
BLU – WHT: 153.4 ± 7%
Thermostat
266 ± 14 (130 ± 8)
5.0
220
1
1/16 (1.3)
2.73 (0.254)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kgs1411