2-3-2. Outdoor Unit
Outdoor unit CG1411
Transformer (TR)
Rating
Coil resistance
Thermal cut-off temp.
Power Relay (PR)
Coil rating
Coil resistance
Contact rating
Thermistor 1 (Discharge pressure)
Resistance
Thermistor 2 (Outlet refrigerant temp.)
Resistance
Reversing Valve
Coil rating
Coil resistance
ON/OFF Valve (Q'ty = 2)
Coil rating
Coil resistance
Check Valve 1 (See Refrigerant Diagram)
Check Valve 2 (See Refrigerant Diagram)
Auto Reset Temperature Limiting
Model
Rating
Thermal Fuse
Model
Cut-off temp.
Primary
Secondary S1
S2
S3
Capacity
Ω (at 70°F (21°C))
Ω (at 68°F (20°C))
kΩ
kΩ
4FF4L510034000
AC 115V, 60Hz
DC 25.4V, 0.25A
DC 12.6V, 0.1A
AC 100V, 1Ma
Primary (ORG – ORG):
Secondary (RED – RED): 5.79 ± 10%
Secondary (BLU – BLU): 8.38 ± 10%
Secondary (YEL – YEL):
277°F (136°C)
AC 250V, 20A
122°F (50°C) 2.2 ± 5%
131°F (55°C) 2.2 ± 5%
CHV-01AE (Coil), CHV-0101 (Valve)
AC115 – 120V, 50/60Hz, 6/5W
NEV-MOAE (Coil), NEV-603DXF (Valve)
AC115 – 120V, 50/60Hz, 7W
FCV-3020D
BCV-804DX
AC125V, 200mA
293°F (145°C)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
8
5VA
71.1 ± 10%
257 ± 10%
DFU24D1F
DC 24V
650 ± 10%
PB3M-41E
PB3M-41E
370
370
CS-7L
X25