GE JGP979 Owner's Manual page 21

Gas downdraft cooktop
Hide thumbs Also See for JGP979:
Table of Contents

Advertisement

Installation
Instructions
[] PREPARING THE COUNTERTOP
Countertop cut-out dimensions
t
Back of Counter
Not less than _5k6" ( 2.4 cm)
2015/16± 1/16"
53.2 ±0.16 cm
28_%6 _ _/_6"
73.3 cm _0.16 cm
r
A
Front of Counter
I
1_91._
Not less than 1¼"
8W_d' min. cut4)ut
/
"_IP_ !
4.8 cm
to wall (22.2 cm)
8_3/_6 " min. cut-out
to wall (22.2 cm)
Cut
out
the
opening
as shown
in the
diagram.
Measure
carefully
when
cutting
the
countertop,
making
sure
the
sides
of the
opening
are
parallel
and
the
fl'ont
and
rear
cuts
are
exactly
perpendicular
to the
sides,
The
fl'ont
of the
opening
must
clear
the
fl'ont
support
rail
on
the
cabinet
and
the
rear
of the
opening
must
clear
the
rear
support
of the
cabinet.
Chandi_r
all exposed
edges
of decorative
laminate
to prevent
danmge
ti'om chipping.
Radius
corners
of cutout
m_d file to ensure
smooth
edges m_d prevent
corner
cracking.
Rough
edges inside
corners
which
have not been
rounded
and forced
fit can contribute
to cracking
of the countertop
laminate,
Countertop
must be supported
within
3" (7.6 cm)
of cutout.
[]
GAS AND ELECTRICAL
LOCATION
The position
of
the electrical
supply
receptacle
and
the gas supply
pipe entering
the
cabinet
should
be
positioned
as
shown
in the
shaded areas
ptacle
marked
below.
[] Gas inlet
The cooktop
is Areas suitable for gas and electrical supply.
equipped
with a 4it
(1.2 m) power
cord,
which
should
reach
any desired
location
on the cabinet
walls. The cooktop
ii/t]st be disconnected
ti'om the
power
supply
befl_re
any servicing
is carried
Otlt.
[]
PROVIDE ADEQUATE
GAS
SUPPLY
This cooktop
is designed
to operate
on natural
gas
onlv at 5" (12.7 cm) of wa tel" colmn n pressure.
It is
fi)I" tlse
with
nattlral
gas
onlv
and
is not
convertible
to I,P gas.
A pressure
regulator
is to be connected
in series
with the manifold
of the cooktop
and must
remain
in series
with the supply
line,
For proper
operation,
the nmxinmm
inlet
pressure
to the regulator
must
be no more
than
10" (25.4 cm) water cohunn
pressure
fl)r natural
gas. For checking
the regulatoi;
the inlet
pressure
must
be at least 1" (2.5 cm) greater
than
the
regulator
output
setting,
If the regulator
is set for
5" (l 2.7 cm) of water
cohmm
pressure,
the inlet
pressure must be at least 6" (l 5.2 cm).
For ease of installation,
and if local codes permit,
the gas supply
line into
the cooktop
should
be
1/2"
(13 ram)
or 3/4"
(19 ram)
I.D. flexible
metal
appliance
connector
three
(0.9 m) to five
ti_et (1.5 m) in length.
[]
PRESSURE TESTING
The nmxinmm
gas supply
pressure
for the
regulator
supplied
on this appliance
is 14"
(35.5 cm) _4'.C. The
test pressure
tor checking
this regulator
must be at least 6" (15.2 cm) W.C.
for natural
gas. It is shipped
ti'om the thctorv
set
for natural
gas at 5" (12.7 cm) W.C.
This appliance
and its individual
shut-oil
valve
must
be disconnected
ti'om
the gas supply
piping
system
during
any pressure
testing
of that system
at test pressures
in excess of ½ PSIG.
This appliance
m list be isolated
fl'om
the gas
supply
piping
system
by closing
its individual
manual
shut-off
valve during
any pressure
testing
of the gas supply
piping
system
at test pressures
equal
to or less than
K, PSIG.
21

Advertisement

Table of Contents
loading

Table of Contents