Brocade Communications Systems PowerConnect B-RX Release Note page 40

Multi-service ironware software release 02.8.00a for brocade bigiron rx series switches
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

Defect ID: DEFECT000350901
Summary:
IPv6 SNMP-client not displayed in running configuration.
Symptom:
Unable to add "snmp-client ipv6 2606:8200::ffff" to the configuration. When configuring the clause, the
system seemed to take the command without any warning, but running configuration did not appear to save it.
Feature: SNMP Management
Probability: High
Found in Release: RX 02.7.02
Defect ID: DEFECT000279953
Summary:
STP BPDUs may be dropped across the Q-in-Q link
Feature: L2 Protocol
Probability: Medium
Found in Release: RX 02.7.02
Where Else Fixed: PATCH: RX 02.7.02 e
Defect ID: DEFECT000343291
Summary:
gig-default neg-off previously configured as gig-default auto-full does not activate link
Symptom:
A "gig-default auto-full" configured port does not get to link up state if the other end of the link has "auto
negotiation" disabled on the port. To get the link up, must remove "gig-default auto-full" once and then add it
again.
Feature: SYSTEM
Probability: Medium
Found in Release: RX 02.7.02
IronWare Software Release 02.8.00a for Brocade BigIron RX Series Swtches
Release Notes v 1.0
Technical Severity: Medium
Function: CLI
Service Request ID: 613853
Technical Severity: Medium
Function: STP
Service Request ID: 238581
Technical Severity: Medium
Function: Auto-negotiation
Service Request ID: 555549