Closed defects with code change in Multi-Service IronWare Release
02.8.00a
Defect ID: DEFECT000350761
Summary:
Under certain VRRP configurations Application Buffers may become depleted.
Symptom:
Under certain VRRP configurations Application Buffers may become depleted causing unexpected reset of the
LP.
Feature: VRRP
Probability: Medium
Found in Release: RX 02.7.03
Defect ID: DEFECT000325041
Summary:
SNMP PIM interface table query returns inaccurate data.
Symptom:
CLI command "show ip pim int" does not display all interfaces and displays an incorrect mask.
Feature: SNMP Management
Probability: High
Found in Release: RX 02.7.03
Defect ID: DEFECT000355837
Summary:
Message buffer depletion on management module is possible when duplicate IP address is detected.
Symptom:
In rare conditions, due to buffer depletion all the LPs may reset due to the loss of heartbeat
Feature: SYSTEM
Probability: Medium
Found in Release: RX 02.7.03
Defect ID: DEFECT000362014
Summary:
The CLI command "show memory" may show a negative value for os_malloc count and os_free count, after
some time.
Symptom:
Display problem only in the "show memory" values for os_malloc count and os_free count showing negative
values.
Feature: SYSTEM
Probability: Low
Found in Release: RX 02.7.02
IronWare Software Release 02.8.00a for Brocade BigIron RX Series Swtches
Release Notes v 1.0
Technical Severity: Critical
Function: VRRPE
Service Request ID: 601157
Technical Severity: Medium
Function: Multicast Mib
Service Request ID: 264854
Technical Severity: Medium
Function: SNM
Service Request ID: 631847
Technical Severity: Medium
Function: Flash memory
Service Request ID: 646359
Page 31 of 40