Defect ID: DEFECT000340501
Summary:
Issuing the OSPF command 'no ip ospf network point-to-point' on VE interface may cause an unexpected reset.
Symptom:
After changing the OSPF parameter 'no ip ospf network point-to-point' on a VE (VE71).the router reset
immediately.
Feature: OSPF
Probability: Medium
Found in Release: RX 02.7.02
Defect ID: DEFECT000300236
Summary:
RX only sends SNMPv1 traps, and there is no way to generate traps in SNMPv2 or SNMPv3.
Symptom:
Unable to generate traps in SNMPv2 or SNMPv3.
Feature: SNMP Management
Probability: Medium
Found in Release: RX 02.7.02
Defect ID: DEFECT000336870
Summary:
New power supplies are showing up as AC power supply, when "show chassis" command is executed, even
though it is a DC power supply.
Symptom:
DC power supplies are showing up as AC power supplies, when "show chassis" command is executed.
*** BigIron RX-16 CHASSIS ***
---POWERS ---
Power 1 (32009000 - DC 1200W): Installed (OK)
Power 2 (32009000 - DC 1200W): Installed (OK)
Power 3 (32009000 - DC 1200W): Installed (OK)
Power 4: Installed (Failed)
Power 5 (32009000 - DC 1200W): Installed (OK)
Power 6 (32009000 - DC 1200W): Installed (OK)
Power 7 (32050 - AC 1200W): Installed (OK)
Power 8 (32050 - AC 1200W): Installed (OK)
Total power budget for chassis = 8400W
Feature: SYSTEM
Probability: High
Found in Release: RX 02.7.02
Defect ID: DEFECT000343072
Summary:
BGP session resets after generating invalid MBGP update with large attribute size.
Feature: BGP
Probability: Medium
Found in Release: RX 02.7.02

IronWare Software Release 02.8.00a for Brocade BigIron RX Series Swtches

Release Notes v 1.0
Technical Severity: High
Function: CONFIGURATION
Service Request ID: 552751
Technical Severity: Medium
Function: Trap/Notification
Service Request ID: 249438
Technical Severity: Medium
Function: POWER SUPPLY
Service Request ID: 522907
Technical Severity: Medium
Function: BGPv4
Service Request ID: 550649